Basic procedure
On the PG/PC with Windows XP:
● Connecting a PG/PC to a PCU according to one of the configurations shown above.
● The network protocol used is: TCP/IP.
● Setting up IP addresses on the same subnetwork.
● Releasing a directory on the PG/PC for network access.
On the PCU under WinPE:
● Start the ServiceCenter under WinPE on the PCU.
● Establish a network connection to the released directory of the PG/PC.
● Using the "Backup" function, a ghost image of the PCU hard disk is saved in the released
● With the "Restore" function, the hard disk of the PCU is restored from a ghost image in
See also
How to backup and restore the hard disk (Page 78)
PCU-Basesoftware (IM8)
Commissioning Manual, 02/2012, 6FC5397-1DP40-3BA0
TCP/IP is already pre-configured in the basic PCU software.
directory of the PG/PC in the event of a need for service.
the released directory of the PG/PC.
4.2 Operating the service PC or the PG on the network
Backing up and restoring data
83