General settings
6.11 Program selection
Example
DB60.DBB10 for data block 60, byte 10
Reserves the bytes 10, 11, 12, 13, 14, 15, 16, 17 as HMI monitor
DB60.DBB10: PLC-ID of the active operating area
DB60.DBW12: PLC-ID of the window that is currently selected
Note
When using the HMI monitor, the corresponding variables in the PLC user interface –
DB19.DBB21 and DB19.DBW24 – are no longer supplied.
This means that either the user interface or the HMI monitor can be used – but not both
simultaneously.
6.11
Program selection
6.11.1
Displaying the softkey
The softkeys on the user interface for calling the program lists are activated via general
configuration machine data.
Configuring a softkey
MD51041 $MNS_ENABLE_PROGLIST_USER
0
1
MD51043 $MNS_ENABLE_PROGLIST_MANUFACT
0
1
66
No softkey
The "Prog. list" softkey is displayed
No softkey
The "MANUFACTURER" softkey is displayed
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
SINUMERIK Operate (IM9)