Show Fip-Snooping Enode - Dell S6000 Reference Manual

Command line for the system
Hide thumbs Also See for S6000:
Table of Contents

Advertisement

show fip-snooping enode

Display information on the ENodes in FIP-snooped sessions, including the ENode interface and MAC
address, FCF MAC address, VLAN ID and FC-ID.
Syntax
show fip-snooping enode [enode-mac-address]
Parameters
enode-mac-
address
Command
Modes
Command
This guide is platform-specific. For command information about other platforms,
History
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version
8.3.19.0
Version
8.3.12.0
Usage
The following describes the show fip-snooping enode command shown in the
Information
following example.
Field
ENode MAC
ENode Interface
FCF MAC
VLAN
FC-ID
Example
Dell# show fip-snooping enode
Enode MAC
--------- --------------- ------- ---- -----
d4:ae:52:1b:e3:cd Te 0/11
62:00:11
572
Enter the MAC address of the ENodes to display.
EXEC
EXEC Privilege
Introduced on the S4820T.
Introduced on the S4810.
Description
MAC address of the ENode.
Slot/ port number of the interface connected to the ENode.
MAC address of the FCF.
VLAN ID number the session uses.
Fibre Channel session ID the FCF assigns.
Enode Interface FCF MAC
54:7f:ee:37:34:40 100
VLAN FC-ID
FCoE Transit

Advertisement

Table of Contents
loading

Table of Contents