Show Fip-Snooping Enode - Dell Z9500 Command Reference Manual

Hide thumbs Also See for Z9500:
Table of Contents

Advertisement

show fip-snooping enode

Display information on the ENodes in FIP-snooped sessions, including the ENode interface and MAC
address, FCF MAC address, VLAN ID and FC-ID.
Z9500
Syntax
show fip-snooping enode [enode-mac-address]
Parameters
enode-mac-
address
Command
Modes
Command
This guide is platform-specific. For command information about other platforms,
History
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version
9.7(0.0)
8.3.19.0
8.3.12.0
Usage
The following describes the show fip-snooping enode command shown in the
Information
following example.
Field
ENode MAC
ENode Interface
FCF MAC
VLAN
FC-ID
Example
Dell# show fip-snooping enode
Enode MAC
--------- --------------- ------- ---- -----
d4:ae:52:1b:e3:cd Te 1/11
62:00:11
FIP Snooping
Enter the MAC address of the ENodes to display.
EXEC
EXEC Privilege
Description
Introduced on the Z9500 and S6000-ON.
Introduced on the S4820T.
Introduced on the S4810.
Description
MAC address of the ENode.
Slot/ port number of the interface connected to the ENode.
MAC address of the FCF.
VLAN ID number the session uses.
Fibre Channel session ID the FCF assigns.
Enode Interface FCF MAC
54:7f:ee:37:34:40 100
VLAN FC-ID
771