  • Page 1 DIGITAL CALL SYSTEM...
  • Page 2 http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl...
  • Page 3 INDEX INDEX INTRODUCTION ..................................5 INSTALLATION PARAMETERS OF THE SYSTEM MATIBUS ..................5 TYPES OF INSTALATION ..............................6 CALL MODULE WITH KEYBOARD REF 1052/10…/10D .....................8 CALL MODULE WITH KEYBOARD REF 1052/11…/11D .....................8 CALL MODULE WITH KEYBOARD REF. 1052/15…/15D ....................9 CALL MODULE WITH KEYBOARD REF. 1052/16…/16D ....................9 CALL MODULE WITH KEYBOARD AND CAMERA REF.
  • Page 5 INTRODUCTION WIRES INTRODUCTION INSTALLATION PARAMETERS OF THE SYSTEM MATIBUS Matibus SE is suitable for medium door phone and video door phone installations. Matibus SE is ideal for making new systems LOCATION DEVICES and modernizing old ones. All equipment should be installed in dry and ventilated places, it is BASIC FEATURES OF THE MATIBUS SE recommended that it is assembled in special boxes designed for this purpose.
  • Page 6 TYPES OF INSTALATION TYPES OF INSTALATION INSTALATION WITH SEVERAL MAIN ENTRANCE PANELS INSTALATION WITH ONE ENTRANCE PANEL Connection up to 240 entrance panels and max. 510 door phones Connection one entrance panel and max. 255 door phones (using (using two risers in power unit). one riser in the power unit).
  • Page 7 TYPES OF INSTALATION VIDEO DOORPHONE INSTALATION WITH ONE ENTRANCE PANEL Connection one entrance panel and max. 127 video door phones (using one riser in the power unit) or 254 video doorphones (using two risers in the power unit). VIDEO DOORPHONE INSTALATION WITH SEVERAL ENTRANCE PANELS Connection up to 240 entrance panels to each power unit and max.
  • Page 8 CALL MODULE WITH KEYBOARD REF. 1052/10../10D CALL MODULE WITH KEYBOARD REF. 1052/11../11D CALL MODULE WITH KEYBOARD CALL MODULE WITH KEYBOARD REF. 1052/10…/10D REF. 1052/11…/11D BASIC FEATURES BASIC FEATURES Digital call module with keyboard ref. 1052/11…/11D Is designed for digital call system MATIBUS and is based on MIWUS call Digital call module with keyboard ref.
  • Page 9 CALL MODULE WITH KEYBOARD REF. 1052/15../15D CALL MODULE WITH KEYBOARD REF. 1052/16../16D CALL MODULE WITH KEYBOARD CALL MODULE WITH KEYBOARD REF. 1052/15…/15D REF. 1052/16…/16D BASIC FEATURES BASIC FEATURES Digital call module with keyboard ref. 1052/16…/16D Is designed Digital call module with keyboard ref. 1052/15…/15D Is designed for digital call system MATIBUS and is based on MIWUS call for digital call system MATIBUS...
  • Page 10 OPERATION INSTRUCTION DESCRIPTION OF TERMINAL BOARDS OPERATION INSTRUCTION Voice line DEFAULT SETTINGS OF USER CODES GND. Data line. Power supply is default programmed for the first 50 user codes in Additional control terminal for video version the first riser. Default, first riser handle user codes in range 1-50, Contacts input/output ground.
  • Page 11 OPERATION INSTRUCTION PROGRAMING MODE Individual opening code can be turned off in a programming mode. PROGRAMING MODE If the door is opened by the individual opening code in the house phone will be played short, confirmation signal and this function Matibus SE call module is coming with already elementary also can be turned off in the programming module.
  • Page 12 PROGRAMMING MODE LU line configuration Advanced functions Keyboard backlight adjustment. Default settings restore. Parameters (change only if it is necessary, always Switch on switchboard. 001-009 consult with manufacturer first). Programming number of keyboard uniting logical entry EXI with EO of power supply in additional Main setup channel.
  • Page 13 PROGRAMMING MODE To save entered parameters press - - - - Default settings 0.1 – 0.9 PARAMETERS 1.05 SOUND LEVEL OF THE KEYBOARD These parameters can be changed only if all else fails, when system works improperly (for example problems with making a call) P 1 0 5 and all other possible source of problems are eliminated.
  • Page 14 PROGRAMMING MODE 1.07 GENERAL OPENING CODES MODE 2. TIME SETTINGS 2.01 ELECTRICAL LOCK-TIME OF WORKING P 1 0 7 P 2 0 1 Parameter sets in this step determine range of using general opening codes. After pressed the button on the LED display will be shown actual General opening codes turned off.
  • Page 15 PROGRAMMING MODE 2.05 RELAY ACTIVATION TIME NC-C-NO 3.05 DELETING ALL DALLAS KEYS P 2 0 5 P 3 0 5 After pressed the button on the LED display will be shown actual To activate this function please press button. During this process on LED display will be shown this communication: programmed time in seconds.
  • Page 16 PROGRAMMING MODE 4.02 INDIVIDUAL OPENING CODES RESTORE 4.09 DEFAULT SETTINGS P1 P2 AND P7 RESTORE P 4 0 2 P 4 0 9 This feature applies to restore: To activate this function please press button. During this process • on LED display will be shown this communication: Restore main setup, •...
  • Page 17 PROGRAMMING MODE In every moment of programming we are able to stop by pressing o o o o ∗ ∗ ∗ ∗ button. Logic code can be associated just to the one physical code. If logical code is already associated with some opening code, this opening code will be shown on the LED display.
  • Page 18 PROGRAMMING MODE 5.05 DALLAS KEY PROGRAMING 5.07 DALLAS KEY IDENTIFICATION This step allows you to identify Dallas key. P 5 0 5 P 5 0 7 Dallas key programming consist on assigned key or keys to each user (each logical user code) Pressing the button, on the LED will be shown this communication:...
  • Page 19 PROGRAMMING MODE Another pressing the button will show the rest part of the serial Another pressing the button will shown therest part of the version number: of software, for call module serial number of software 0718 the LED display will show: 6.03 MENSURATION THE CURRENT IN RISER 1 7.
  • Page 20 PROGRAMMING MODE 7.03 PROGRAMMING NUMBER KEYBOARD programming mode, set the frequency of the voltage which show on TERMINAL POWER SUPPLY the terminals +CL –CL. ADDITIONAL CHANNEL Below table shows dependence between chosen parameter and frequency of electric lock: Parameter Freqency P 7 0 3 500Hz 250Hz...
  • Page 21 PROGRAMMING MODE 8. MASTER/SLAVE FUNCTIONS If physical code has been already associated, than the LED display 8.01 CHANGE THE ID OF MASTER POWER SUPLLY shows programmed code. Than we are able to: • Keep previous code or enter new one in range from 1-9999, P 8 0 1 than confirm, •...
  • Page 22 PROGRAMMING MODE 9. FEATURES THAT IMPROVE L. L. L. L. 9.01 DEACTIVATION “OFF” INFORMATION P 9 0 1 Enter logical user code for the main channel, confirm pressing the button. This step allows you to deactivate displaying “OFF” information in If logical user code for additional channel is already assigned, case of lack called door phone.
  • Page 23 PROGRAMMING MODE 9.09 UPDATING CALL MODULE KEYBOARD SOFTWARE To save parameter press button. Default settings P 9 0 9 9.05 COMMUNICATION MODE IN THE ADDITIONAL CHANNEL This step allows updating call module keyboard software. Press the P 9 0 5 button to enter this step and update the keyboard.
  • Page 24 ERRORS REPORT ADJUSTMENT ADJUSTMENT CALL MODULES 1052/10../10D, ERRORS REPORT 1052/11…/11D, 1052/15…/15D, 1052/16…/16D Call modules detect and identify lots of errors in Matibus SE system. Communication about detected errors will be shown on the Panel’s PCB is pre-adjusted during the manufacturing process. LED display with correct code credited to specific error.
  • Page 25 ACTIVATING THE SYSTEM 11. Check audio in main entrance panels: ACTIVATING THE SYSTEM Call one of the door phone. In case of problem with audio: - check connection and installation, MASTER check terminal voltage keyboard (7,5 .. 12,5 V DC). 12.
  • Page 26 MOUNTING PANELS 1052/10 AND 1052/15 Slip the PCB assembly kit into latches located in the top part of MOUNTING PANELS 1052/10..10D AND the case. 1052/15..15D Press down part of the PCB assembly kit. 10. Connect the wires. Important: The module should not be illuminated from behind to 11.
  • Page 27 MOUNTING PANELS 1052/11 AND 1052/16 MOUNTING PANELS 1052/11..11D AND FLUSH-MOUNTED VERSION 1052/16..16D For flush-mounted version is recommend using the frame Ref. 525/RP3. Important: The module should not be illuminated from behind to Take out the front keyboard panel. make the calling module display easier to read. Never direct the module towards strong sources of light.
  • Page 28 CALL MODULE WITH CAMERA REF. 1752/11 CALL MODULE WITH CAMERA REF. 1752/16 CALL MODULE WITH KEYBOARD AND CALL MODULE WITH KEYBOARD AND CAMERA REF. 1752/11…/11D CAMERA REF. 1752/16…/16D BASIC FEATURES BASIC FEATURES Digital call module with keyboard, b/w camera, Dallas key reader Digital call module...
  • Page 29 TECHNICAL SPECIFICATION OPERATION AND PROGRAMMING INSTRUCTION OPERATION AND PROGRAMMING TECHNICAL SPECIFICATION INSTRUCTION ~ 12 V AC Power supply voltage To choose kind of transmission video signal please use + 20 V DC dip-switches S1 and S2. • Set both dip-switches S1 and S2 in A-B position to use UTP -with build in three state regulation cable for video transmission (transmission in differential way) of current U...
  • Page 30 MOUNTING PANELS 1752/11 AND 1752/16 MOUNTING PANELS 1752/11..11D AND FLUSH-MOUNTED VERSION 1752/16..16D For flush-mounted version is recommend using the frame Ref. 525/RP3. Important: The module should not be illuminated from behind to Take out the front keyboard panel. make the calling module display easier to read. Never direct the module towards strong sources of light.
  • Page 31 MOUNTING PANELS 1752/11 AND 1752/16 Fig. 9. http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl...
  • Page 32 SINTHESI CALL MODULE REF. 1052/13 SINTHESI CALL MODULE WITH KEYBOARD REF. 1052/13 TECHNICAL SPECIFICATION ~ 12 V AC Power supply voltage + 20 V DC BASIC FEATURES -with build in three state regulation of current U =12V Digital call module with keyboard ref. 1052/13 is designed for Driving of electrical lock -NO–C–NC maximum value 1A/24V digital call system MATIBUS...
  • Page 33 OPERATION INSTRUCTION SERIAL NUMBER OF CALL MODULE OPERATION INSTRUCTION To see serial number please go follow the instructions: DEFAULT SETTINGS OF USER CODES -first push this buttons combination 0X2 then you will see less significant part of serial number. Power supply is default programmed for the first 50 user codes in - Press to show you the rest part of serial number.
  • Page 34 OPERATION INSTRUCTION PROGRAMMING MODE Individual opening code can be turned off in a programming mode. PROGRAMING MODE If the door is opened by the individual opening code in the house phone will be played short, confirmation signal and this function Matibus SE call module is coming with already elementary...
  • Page 35 PROGRAMMING MODE LU line configuration Advanced functions Keyboard backlight adjustment. Default settings restore. Parameters (change only if it is necessary, always Switch on switchboard. 001-009 consult with manufacturer first). Programming number of keyboard uniting logical entry EXI with EO of power supply in additional Main setup channel.
  • Page 36 PROGRAMMING MODE 0.01 – 0.09 PARAMETERS 1.05 SOUND LEVEL OF THE KEYBOARD These parameters can be changed only if all else fails, when system works improperly (for example problems with making a call) P 1 0 5 and all other possible source of problems are eliminated. 1.
  • Page 37 PROGRAMMING MODE 1.07 GENERAL OPENING CODES MODE To save entered changes press Default settings P 1 0 7 2.02 TIME OF CALLING SIGNAL Parameter sets in this step determine range of using general P 2 0 2 opening codes. General opening codes turned off. Function active for lock output (+CL, -CL) Function active for relay output (NC-C-NO) After pressed the...
  • Page 38 PROGRAMMING MODE 3. DATA DELETE 3.06 DELETING ALL DIGITISER DATA 3.01 DELETING ALL LOGICAL USER CODES SLAVE P 3 0 6 P 3 0 1 To activate this function please press button. During this process To activate this function please press button.
  • Page 39 PROGRAMMING MODE 4.03 GENERAL OPENING CODES RESTORE 5. LOGICAL USER AND OPENING CODES 5.01 LOGICAL USER CODES PROGRAMMING P 4 0 3 P 5 0 1 To activate this function please press button. During this process on LED display will be shown this communication: After pressing the button on the LED display will be shown this communication:...
  • Page 40 PROGRAMMING MODE 5.02 RE-MAPPING LOGICAL USER CODES 5.04 GENERAL OPENING CODES PROGRAMMING P 5 0 2 P 5 0 4 After pressing the button on the LED display will be shown this You can program 64 general opening codes with the possibility of communication: individual assignment to specific keyboard.
  • Page 41 PROGRAMMING MODE • 6. SERVICE FUNCTIONS The keyboard should beep twice to confirm. In case of failure, 6.01 SERIAL NUMBER OF THE POWE SUPPLY the keyboard generate warning signal, LED displays Er12. It means that Dallas key is faulty or it is already assigned to other user.
  • Page 42 PROGRAMMING MODE Entering in this function we are able to get known approximate 7. ADVANCED FUNCTIONS 7.00 KEYBOARD BACKLIGHT ADJUSTMENT value of current in riser 2, measuring instrument is in mA. P 7 0 0 6.05 POWER SUPPLY SOFTWARE VERSION P 6 0 5 This step allows you to adjust the brightness of the keyboard backlight.
  • Page 43 PROGRAMMING MODE 7.03 PROGRAMMING NUMBER KEYBOARD 7.06 FREQUENCY OF ELECTRIC DOOR LOCK MODE TERMINAL POWER SUPPLY ADDITIONAL CHANNEL P 7 0 6 P 7 0 3 In this step we are programming frequency of electric door lock mode, which is connected to call module by terminals +CL –CL. In this step we are able to set the number of call module keyboard, These terminals are able to service electric door lock for DC and by this module we can turn on NC-C-NO relay exit, if we turn on...
  • Page 44 PROGRAMMING MODE • 7.09 MODES ELECTRICAL DOOR LOCK Confirm by pressing the button If the physical code was not associated with any logical user code P 7 0 9 the LED displays this communication: 0 – normal, L L L L 1 –...
  • Page 45 PROGRAMMING MODE 9. FEATURES THAT IMPROVE 1 2 3 4 9.01 DEACTIVATION “OFF” INFORMATION P 9 0 1 If logical user code for additional channel is not assigned, after pressing the button LED displays this communication: This step allows you to deactivate displaying “OFF” information in L.
  • Page 46 PROGRAMMING MODE 9.05 COMMUNICATION MODE IN THE ADDITIONAL CHANNEL 9.09 UPDATING CALL MODULE KEYBOARD SOFTWARE P 9 0 5 P 9 0 9 This step allows setting communication mode in the additional This step allows updating call module keyboard software. Press the channel.
  • Page 47 ERRORS REPORT ERRORS REPORT Call modules detect and identify lots of errors in MATIBUSse system. Communication about detected errors will be shown on the LED display with correct code credited to specific error, based on this communication we are able to define what kind of error is that. In the table below we present list of errors code with explanation.
  • Page 48 ACTIVATING THE SYSTEM 11. Check audio in main entrance panels: ACTIVATING THE SYSTEM 12. Call one of the door phone. In case of problem with audio: - check connection and installation, MASTER check terminal voltage keyboard (7,5 .. 12,5 V DC). 13.
  • Page 49 INSTALLATION Fit the module in the frame. INSTALLATION The Call Module must be installed on Sinthesi frame (not provided). The anti-theft screw provided must be used instead of the normal screw furnished with the Sinthesi frame in order to guarantee installation security.
  • Page 50 INSTALLATION FLUSH-MOUNTED VERSION WITH WALL-MOUNTED VERSION WITH CASE AND HOOD WALL COVER FRAME The case and hood is provided with frame and module holder Fasten the hood to the wall by means of three bolts. Arrange the The wall cover frames are used to conceal possible irregularity of hole for passing the wires through the lower area of the casing and the wall surrounding the flush-mounting box.
  • Page 51 INSTALLATION http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl...
  • Page 52 HOUSE PHONE REF. 1131/520 TECHNICAL SPECIFICATION supply ref. 1052/31A (the maximum number of users 510) code HOUSE PHONE REF. 1131/520 house phones equal to the value set by jumpers in binary code (for riser nr.1) and code calls will be equal to the number set by jumpers plus the number of 255 (for riser No.2).
  • Page 53 HOUSE PHONE REF. 1131/521 TABLE-TOP MOUNTING KIT REF. 1130/120 HOUSE PHONE WITH ADDITIONAL BUTTON TABLE-TOP MOUNTING KIT REF. 1130/120 REF. 1131/521 BASIC FEATURES Door phone 1131/520 and 1131/521 can be table mounted using kit ref. 1130/120. BASIC FEATURES Door phone ref. 1131/521 is based on ref. 1131/520, but it is provided with additional button, and ready for fitting other 3 supplementary buttons.
  • Page 54 HOUSE PHONE REF. 1132/520 TECHNICAL SPECIFICATION house phones equal to the value set by jumpers in binary code (for HOUSE PHONE REF. 1132/520 riser nr.1) and code calls will be equal to the number set by jumpers plus the number of 255 (for riser No.2). Jumpers location Physical address CALL VOLUME ADJUSTMENT...
  • Page 55 HOUSE PHONE REF. 1132/520 TABLE-TOP MOUNTING KIT REF. 1332/51 HOUSE PHONE WITH ADDITIONAL BUTTON TABLE-TOP MOUNTING KIT REF. 1332/51 REF. 1132/521 BASIC FEATURES Door phone 1132/520 and 1132/521 can be table mounted using kit ref. 1332/51. BASIC FEATURES Door phone ref. 1132/521 is based on ref. 1132/520, but it is provided with additional button, and ready for fitting other 6 supplementary buttons.
  • Page 56 HOUSE PHONE REF. 1132/620 TECHNICAL SPECIFICATION The house phone physical address is set with jumpers. We can set HOUSE PHONE the phone number from 1 to 255. The first jumper (from right) is the REF. 1132/620 number 1. We use only first 8 jumpers (from right) and the other two are used for testing house phone.
  • Page 57 HOUSE PHONE REF. 1132/621 TECHNICAL SPECIFICATION HOUSE PHONE REF. 1132/621 BASIC FEATURES Door phone ref. 1132/621 is based on ref. 1132/620, but it is provided with additional button, and ready for fitting other 6 supplementary buttons. Additional button can be used for: calling switchboard, control NO- NC relay etc.
  • Page 58 VIDEO DOOR PHONE REF. 1202/1A BASIC FEATURES VIDEO DOOR PHONE WINFLAT REF. 1202/1A BASIC FEATURES The Winflat video door phone ref. 1202/1A features a flat, B/W 4” monitor screen. Thanks to small dimension, Winflat can be installed on the wall without the need of forging the wall. The Winflat has adjustable call tone volume, brightness and contrast.
  • Page 59 BRACKET CONFIGURATION WINFLAT BRACKET REF. 1202/952 Switch Description Settings Function Address Physical address settings settings 1 2 3 4 5 6 7 8 Termination ON Video line (UTP) termination Termination OFF button implement video button auto on function configuration Service button active Floor call terminals Y1 Y2...
  • Page 60 BRACKET CONFIGURATION OPERATION INSTALATION VIDEO AUDIO-ON Arrange the duct so that it ends in correspondence with one of the input holes. Video audio-on function demands one additional wire in the Fasten the bracket to the wall at the height from the floor installation between bracket’s terminal R3 and terminal R in the call shown by means of the four screws.
  • Page 61 POWER SUPPLY “MASTER” REF. 1052/31A POWER SUPPLY „MASTER” DESCRIPTION OF TERMINAL BOARDS REF. NO. 1052/31A Input voltage ~0 V. ~115 Input voltage ~ 115 V AC. ~230 Input voltage ~230 V AC. Output 12 V AC. Output 12 V AC. Addictional data line.
  • Page 62 POWER SUPPLY “MASTER/SLAVE” REF. 1052/33 POWER SUPPLY „MASTER/SLAVE” DSECRIPTION OF TERMINAL BOARDS REF. NO. 1052/33 Input voltage ~0 V. ~115 Input voltage ~ 115 V AC. ~230 Input voltage ~230 V AC. Output 12 V AC. Output 12 V AC. Addictional data line.
  • Page 63 ADDITIONAL POWER SUPPLY REF. 1052/20 VIDEO POWER SUPPLY REF. 789/7P ADDITIONAL POWER SUPPLY VIDEO POWER SUPPLY REF. 789/7P REF. 1052/20 BASIC FEATURES BASIC FEATURES The additional power supply ref. 1052/20 is used in the systems Video power supply unit ref. 789/7P is used to supply the camera with multi entrances structure only for power modules call.
  • Page 64 VIDEO DISTRIBUTOR REF. 1752/54 VIDEO DISTRIBUTOR REF. 1752/54 TECHNICAL SPECIFICATION Power voltage 18 - 20 V DC Consumption in stand by 15 mA mode: Consumption 150 mA Dimension (WxHxD) 95 x 64 x 28 mm INFORMACJE OGÓLNE In large installation with a lot of distributors keep in mind do not exceed current load of power supply.
  • Page 65 VIDEO DISTRIBUTOR REF. 1794/4 SID VIDEO DISTRIBUTOR REF. 1794/4 SID BASIC FEATURES Distributes the video signal in systems with COAX cable. The typical uses of this product are video signal distribution on floor level and distribution of the same video signal on several riser columns.
  • Page 66 RELAY SWITCH FOR VIDEO SYSTEM REF. 1032/9 RELAY SWITCH FOR SPECIAL VIDEO DOOR TECHNICAL SPECIFICATION PHONE SYSTEM REF. 1032/9 12 V DC Power voltage: 24 V DC Consumption: Stand-by 4 mA Work 27 mA Max. relay contact power 2 A @ 24 V DC Operating temperature 10°C + 45°C Dimension (W x H x D)
  • Page 67 4 OUTPUTS DECODER REF. 1052/34 4 OUTPUTS DECODER door door door door phone phone phone phone REF. 1052/34 Dipswitch settings physical physical physical physical address code code code 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 SWITCHBOARD CALL OR OC CONTROL To call switchboard lift the handset and press additional button.
  • Page 68 DIGITISER REF. 1052/7 TECHNICAL SPECIFICATION DIGITISER REF. 1052/7 DESCRIPTION OF TERMINALS BOARDS Output voltage 12 V AC. Output voltage 12 V AC. GND for data line and voice. Voice line. Data line. Control terminal for video version. Speaker. Speaker. Microphone GND . Microphone.
  • Page 69 DIGITISER REF. 1052/7 PROGRAMMING Dip-switch Group Binary PROGRAMMING Description settings ID SETTING Digitiser „zero” for 2 group ID number is important in systems with several entrances. ID must be unique for each call module (other digitisers and call modules First Digitiser for 2 with keyboard).
  • Page 70 DIGITISER REF. 1052/7 PROGRAMMING BUTTONS PROGRAMING CONFIGURATION AND ADJUSTMENT Associated buttons with door phone: Digitiser connected to the main channel: set number of power unit, which serve relevant door phone. Dip-switch number 1 is the least significant bit. If digitiser is connected to the Desription Settings Function...
  • Page 71 SWITCHBOARD STATION REF. 1052/40 BASIC FEATURES BUS socket is used for connection switchboard with main channel. SWITCHBOARD STATION REF. 1052/40 Mark Description Voice. Not use. Data line. GND. GND. RS232 is used for connection switchboard with PC, for example for download user’s repertory or update the software.
  • Page 72 SWITCHBOARD STATION REF. 1052/40 CONFIGURATION TECHNICAL SPECIFICATION ENTRANCE PANEL ID: Power supply: 12 V DC / 500 mA Enter entrance panel ID and press to confirm. Voltage 0L LG + 7,5…12,5 V DC The following will appear: Voltage 0L D + 15 V DC nom.
  • Page 73 SWITCHBOARD STATION REF. 1052/40 CONFIGURATION 2 RELAY OUTPUTS ENTER NEW PASSWORD Switchboard station has 8 built-in NO-C-NO relays. Activation any of the relays is confirmed by turning on relevant LED. Each relay can be activated by different events, for example calling switchboard from door phone number 1011 will activate relay To change password enter old password, press after that enter...
  • Page 74 SWITCHBOARD STATION REF. 1052/40 CONFIGURATION 9 DEFAULT SETTINGS This option allows you to restore default settings of the switchboard station. The following will appear: DEFAULT SETTINGS RESTORE? Press to exit. Press to confirm. The following will appear: WAIT… Default settings will be restoring in 45 seconds. Default settings restore will erase: •...
  • Page 75 SWITCHBOARD STATION REF. 1052/40 OPERATION INSTRUCTION OPERATION INSTRUCTION 19-10-2007 20:53 EVENT:1 FUNCTIONAL KEYS ∗ • Conversation can be disconnected by pressing button on the Klawisz Opis call module keyboard or by hanging up the handset or pressing on the switchboard station. Day/night switching •...
  • Page 76 SWITCHBOARD STATION REF. 1052/40 OPERATION INSTRUCTION CALL TO DOOR PHONE Press button to view unanswered, storage calls. To call door phone from switchboard station: • • Pick up the handset, to scroll storage calls. • • Dial logical user code for main channel, press to delete Press and hold to enter EVENT OPTION.
  • Page 77 SWITCHBOARD STATION REF. 1052/40 OPERATION INSTRUCTION REPERTORY You can confirm old name by double press .To change the The switchboard station is equipped with built-in repertory with name: firstly delete the old one by several press (delete all capacity up to 1024 users.. characters), enter the new name.
  • Page 78 SWITCHBOARD STATION REF. 1052/40 ADJUSTMENT ERRORS REPORT ADJUSTMENT On display could appear also errors report. The switchboard station is pre-adjusted during the manufacturing process.Potenciometers allow adjustment of the switchboard SWITCHBOARD SWITCH OFF station, however should perform this step only if it is really This message appears, if in 7.1 programming step switchboard necessary function is switched off.
  • Page 79 DIAGRAMS ONE MAIN AUDIO ENTRANCE PANEL http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl...
  • Page 80 DIAGRAMS ONE MAIN AUDIO ENTRANCE PANEL (EXTENDED VERSION) http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl...
  • Page 81 DIAGRAMS THREE MAIN AUDIO ENTRANCE PANELS http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl...
  • Page 82 DIAGRAMS ONE MAIN AND THREE ADDITIONAL AUDIO ENTRANCE PANELS http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl...
  • Page 83 DIAGRAMS MASTER/SLAVE STRUCTURE WITH SWITCHBOARD STATION http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl...
  • Page 84 DIAGRAMS ONE VIDEO ENTRANCE PANEL (COAX VERSION) http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl...
  • Page 85 DIAGRAMS ONE VIDEO ENTRANCE PANEL (COAX VERSION WITH DISTRIBUTORS) http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl...
  • Page 86 DIAGRAMS ONE VIDEO ENTRANCE PANEL (UTP VERSION) http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl...
  • Page 87 DIAGRAMS ONE VIDEO ENTRANCE PANEL (UTP VERSION WITH DISTRIBUTORS REF. 1752/54) http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl...
  • Page 88 DIAGRAMS THREE VIDEO ENTRANCE PANELS (UTP VERSION WITH DISTRIBUTORS) http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl...
  • Page 89 DIAGRAMS DECODER REF. 1052/34 (UTP VERSION WITH DISTRIBUTORS) http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl...
  • Page 90 DIAGRAMS DECODER REF. 1052/34 (UTP VERSION WITH DISTRIBUTORS) http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl...
  • Page 91 DIAGRAMS DECODER REF. 1052/34 (UTP VERSION WITH DISTRIBUTORS) http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl...
  • Page 92 DIAGRAMS ONE ANALOGUE ENTRANCE PANEL (SYSTEM WITH DIGITALIZER) http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl...
  • Page 93 DIAGRAMS THREE ANALOGUE ENTRANCE PANELS (SYSTEM WITH DIGITALIZERS) http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl...
  • Page 94 DIP-SWITCH AND JUMPERS SETTINGS TABLE OF VIDEO BRACKET SETTINGS http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl...
  • Page 95 DIP-SWITCH AND JUMPERS SETTINGS TABLE OF DOOR PHONE SETTINGS http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl...
  • Page 96 DIP-SWITCH AND JUMPERS SETTINGS DIGITALIZER SETTINGS http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl...
  • Page 97 NOTES NOTES http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl...
  • Page 98 MIWI-URMET Co. Ltd. ul. Pojezierska 90A 90-341 Lodz, Poland tel: 004842 616 21 00 fax: 004842 616 21 12 http://www.miwiurmet.com.pl e-mail: miwi@miwiurmet.com.pl...