Motoring torque limit
<1>
M_max upper/mot
-100 000.00...100 000.00 [Nm]
p1520[D]
p1520 (100.00)
M_max up/mot scal
-2000.0...2000.0 [%]
p1524[D]
p1524 (100.0)
M
1
e.g.
n
3
0 = Quick stop activated
(OFF3)
r0899.5
Regenerating torque limit
<1>
M_max lower/regen
-100 000.00...100 000.00 [Nm]
p1521[D]
p1521[D] (0.00)
M_max low/gen scal
-2000.0...2000.0 [%]
p1525[D]
p1525[D] (100.0)
M
2
n
4
<1> For p1400.4 = 1, the first torque limit applies for motoring operation and the other for regenerative operation, independently of the sign of the torque
and the speed (compatible with SIMODRIVE).
"Normal case": If neither dynamic limits nor offsets are required, the torque limit when motoring is entered via p1520. The torque limit when
regenerating is entered via p1521 (as a negative value).
<2>
For the manufacturer-specific PROFIdrive telegrams 102 und 103, r1543 is entered here [5610.4].
<3> With p1400.13 = 0, the following applies: if n_act < p1546, the motor limit is effective.
With p1400.13 = 1, the following applies: if n_set = 0, the regenerative limit is effective.
1
2
DO: SERVO
Servo control - Motoring/regenerating torque limit
0
p1522[C]
(1520)
1
p1528[C]
(1524)
e.g. from MOMRED
<2>
M_lim var/fixS_src
p1551[C]
(1)
p1523[C]
1
(1521)
p1529[C]
0
(1525)
e.g. from MOMRED
<2>
3
4
1400.13
n_ctrl n_set
<3>
[5030.8]
r1438
1
n_act smooth
[4710.6]
r0063
0
M
M_max up w/o offs
1
n
r1526
-1
<0
M
0
2
n
M
n
4
-1
<0
M
0
n
3
M_max low w/o offs
r1527
5
6
fp_5620_98_eng.vsd
17.10.08 V04.04.00
1000.00 μs
M
2
1
n
M_offset
M_max 2
[5640.1]
+
+
M_max offset
-100 000.00...100 000.00 [Nmp]
1532[D] (0.00)
<3>
+
M_offset
M_min 2
[5640.1]
+
M
n
3
4
The 4 quadrants
M
+
2
1
Reverse,
Forward,
generating
motoring
+
Reverse,
Forward,
motoring
generating
3
4
7
8
Function diagram
- 5620 -
SINAMICS S110