Siemens SINAMICS S110 List Manual page 604

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
Index:
[0] = SI checksum to track functional changes
[1] = SI checksum to track hardware-specific changes
Dependency:
Refer to: p9601, p9729, p9799
Refer to: F01690
r9782[0...1]
SI time stamps to check changes (Control Unit) / SI chg t CU
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
- [h]
Description:
Displays the time stamps for the checksums for tracking changes for Safety Integrated.
The time stamps for the checksums for tracking changes (fingerprint for the "safety logbook" functionality) made to
safety parameters are saved in parameters p9781[0] and p9781[1].
Index:
[0] = SI time stamp for checksum to track functional changes
[1] = SI time stamp for checksum to track hardware-specific changes
Dependency:
Refer to: p9601, p9729, p9799
Refer to: F01690
p9783
SI motion synchr. motor current injection sensorless / SI Mtn SM Id SL
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
-50.00 [%]
Description:
Sets the field-generating current for sensorless actual value sensing of synchronous motors.
For synchronous motors, this current is fed in using sensorless safety functions.
The value must fulfill the following condition: |p0305 x p9783| >= p9588 x 1.2
Dependency:
Refer to: p9588
Refer to: C01711
Notice:
Reducing this percentage value can adversely affect actual value sensing with synchronous motors.
If the value is increased, this results in an increased motor power loss.
Note:
This parameter is only effective for encoderless actual value sensing (p9306/p9506 = 1).
r9794[0...19]
SI crosswise comparison list (processor 1) / SI CDC_list P1
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Displays the numbers of the data items that are currently being compared crosswise on processor 1.
The content of the list of crosswise-compared data is dependent upon the particular application.
Dependency:
Refer to: r9894
Note:
Example:
r9794[0] = 1 (monitoring clock cycle)
r9794[1] = 2 (enable safety functions)
r9794[2] = 3 (F-DI changeover, tolerance time)
...
A complete list of numbers for crosswise-compared data items appears in fault F01611.
1-604
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [h]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
0.00 [%]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [h]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-20.00 [%]
Access level: 3
Func. diagram: 2802
Unit selection: -
Expert list: 1
Factory setting
-

Hide quick links:

Advertisement

Table of Contents
loading