4000.00 μs
Refer to [1020.7]
Ramp-function generator selection
n_set_4
[3060.8]
From the basic ramp-function generator
n_set_5
[3070.8]
From the expanded ramp-function generator
Torque limit reached
[2522.7]
r1407.7
<1>
For p1145 > 0, ramp-function generator tracking is activated when the torque limiting
responds. This means that the speed controller output only exceeds the torque limit by a
deviation that can be set via p1145.
<2>
For OFF1/OFF3, the ramp-function generator ramp is active. The ramp-function generator is
set to the actual value and stops the drive with the ramp-downtime (p1121 or p1135). STW1.4
(enable ramp-function generator) is effective while the drive is stopped via the ramp-function
generator. Depending on the p1115, the basic ramp-function generator [3060] or the extended
ramp-function generator [3070] is effective. When the function module "extended setpoint
channel" (r0108.8 = 0) is not active for OFF1/OFF3, the down ramp of the basic ramp-function
generator is effective (refer to n_set_4 on [3060.8]).
<3>
The interpolator is only effective for clock-cycle synchronous PROFIBUS operation and sign-
of-life received from the master (STW2.12 ... STW2.15).
<4>
Behavior of the response ramp of the torque limiting:
p1145 = 0.0: No ramp-function generator tracking. The ramp-function generator ramp is no longer in the range of the speed
actual value.
p1145 = 1.0: The ramp-function generator ramp remains as close as possible to the speed actual value.
p1145 > 1.0: The ramp-function generator ramp is steeper than for p1145 = 1.0 (higher "speed following error").
<5>
For SERVO, the following applies: Only when the function module "extended setpoint channel" is activated (r0108.8 = 1).
<6>
The value is displayed correctly only with r0899.2 = 1 (Operation enabled).
1
2
DO: SERVO
Setpoint channel - Ramp-function generator selection, status word, tracking
Enable ramp-function generator
from the
r0898.4
STW
Enable speed setpoint
sequence
r0898.6
control
Jog 1
[2501.7]
r0898.8
Jog 2
r0898.9
n_ctrl n_set 1
p1155[C]
<2>
(0)
n_ctrl n_set 2
p1160[C]
<2>
(0)
RFG selection
p1115
RFG n_set at the output
0
r1150
RFG tracking intensity
1
0.0...50.0
p1145[D] (1.3)
<4>
[3060.8]
[3070.8]
[3060.8]
[3070.8]
[3080.8]
[3050.8]
3
4
1
<3>
p1189.1
x,y
T1
x
1
1
+
0
0
0
Interpolator
Expanded
setpoint channel
p1189.0
r0108.8
<5>
x,y
T1
x
0
1
0
1
0
Interpolator
Ramp-function generator tracking
Ramp-function generator status word
Bit
Ramp-function generator status word
0
Ramp-up active
1
Ramp-down active
2
Ramp-function generator active
•1
3
Ramp-function generator set
4
Ramp-function generator held
5
Ramp-function generator tracking active
6
Maximum limiting active
7
Reserved
8
Reserved
9
Reserved
10
Reserved
11
Reserved
12
Reserved
13
Reserved
14
Reserved
15
Reserved
5
6
fp_3080_98_eng.vsd
15.07.09 V04.04.00
250.00 μs
Refer to [1020.7]
n_ctrl n_set 1/2
<6>
r1169
x
y
y
No OFF2
&
No OFF3
t
+
0
n_ctrl setp sum
x
r1170
[5020.1]
+
y
[8011.2]
y
1
t
[3060.1]
Ramp flattening-off
[3070.3]
Ramp-function generator tracking active
r1199.5
RFG ZSW
r1199
r1199.2
[8010.5]
<1>
7
8
Function diagram
- 3080 -
SINAMICS S110