Siemens SINAMICS S110 List Manual page 536

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
p9330
SI Motion standstill tolerance (processor 2) / SI Mtn SOS Tol P2
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0.000 [mm]
Description:
Sets the tolerance for the function "Safe Operating Stop" (SOS).
Dependency:
Refer to: p9530
Refer to: C01707
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
SOS: Safe Operating Stop
p9330
SI Motion standstill tolerance (processor 2) / SI Mtn SOS Tol P2
SERVO_S110-CAN
Can be changed: C2(95)
(Safety rot),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Safety Integrated
(Safety rot),
Not for motor type: -
SERVO_S110-PN
(Safety rot)
Min
0.000 [°]
Description:
Sets the tolerance for the function "Safe Operating Stop" (SOS).
Dependency:
Refer to: p9530
Refer to: C01707
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
SOS: Safe Operating Stop
p9331[0...3]
SI Motion SLS limit values (processor 2) / SI Mtn SLS lim P2
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [mm/min]
Description:
Sets the limit values for the function "Safely-Limited Speed" (SLS).
Index:
[0] = Limit value SLS1
[1] = Limit value SLS2
[2] = Limit value SLS3
[3] = Limit value SLP4
Dependency:
Refer to: p9363, p9531
Refer to: C01714
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
SLS: Safely-Limited Speed
1-536
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
100.000 [mm]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
100.000 [°]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1000000.00 [mm/min]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1.000 [mm]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1.000 [°]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
2000.00 [mm/min]