p20258
INT 0 lower limit value LL / INT 0 lower lim LL
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-340.28235E36
Description:
Sets the lower limit value LL of instance INT 0 of the integrator.
p20259
INT 0 integrating time constant in ms / INT 0 T_Integr ms
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
0.00
Description:
Sets the integrating time constant Ti in milliseconds of instance INT 0 of the integrator.
p20260
BI: INT 0 accept setting value S / INT 0 acc set val
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Unsigned32 / Binary
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-
Description:
Sets the signal source for the "accept setting value" signal of instant INT 0 of the integrator.
r20261
CO: INT 0 output Y / INT 0 output Y
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-
Description:
Display parameter for output quantity Y of instance INT 0 of the integrator.
If LL>= LU, then the output quantity Y = LU.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
340.28235E36
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
340.28235E36
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: PERCENT
Max
-
Parameter
List of parameters
Access level: 1
Func. diagram: 7264
Unit selection: -
Expert list: 1
Factory setting
0.0000
Access level: 1
Func. diagram: 7264
Unit selection: -
Expert list: 1
Factory setting
0.00
Access level: 1
Func. diagram: 7264
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 7264
Unit selection: -
Expert list: 1
Factory setting
-
1-723