r9773.0...31
CO/BO: SI status (processor 1 + processor 2) / SI status P1+P2
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Displays the Safety Integrated status on the drive (processor 1 + processor 2).
Bit field:
Bit
Signal name
00
STO selected in drive
01
STO active in drive
02
SS1 delay time active in the drive
04
SBC requested
05
SS1 selected in the drive (Basic Functions)
06
SS1 active in the drive (Basic Functions)
31
Shutdown paths must be tested
Note:
This status is formed from the AND operation of the relevant status of the two monitoring channels.
r9776
SI diagnostics / SI diagnostics
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
The parameter is used for diagnostics.
Bit field:
Bit
Signal name
00
Safety parameter changed POWER ON
required
Note:
Re bit 00 = 1:
At least one Safety parameter has been changed that will only take effect after a POWER ON.
r9780
SI monitoring clock cycle (Control Unit) / SI monitor_clck CU
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
- [ms]
Description:
Displays the clock cycle time for the Safety Integrated Basic Functions on the Control Unit.
Dependency:
Refer to: r9880
r9781[0...1]
SI checksum to check changes (Control Unit) / SI chg chksm CU
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Displays the checksum for tracking changes for Safety Integrated.
These are additional checksums that are created to track changes (fingerprint for the "safety logbook" functionality)
to safety parameters (that are relevant for checksums).
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [ms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Parameter
List of parameters
Access level: 2
Func. diagram: 2804
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
2804
No
2804
No
2804
No
2804
No
-
No
-
No
2810
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
-
Access level: 3
Func. diagram: 2802
Unit selection: -
Expert list: 1
Factory setting
- [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
1-603

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents