Siemens SINAMICS S110 List Manual page 592

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
Note:
This parameter is only supplied with actual values in the case of Safety Integrated Extended Functions. For Safety
Integrated Basic Functions (SBC, SS1, STO), the value is equal to zero.
r9722.0...15
CO/BO: SI Motion status signals integrated in the drive / SI Mtn integ stat
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Status signal for safety-relevant motion monitoring functions integrated in the drive.
Bit field:
Bit
Signal name
00
STO active
01
SS1 active
02
SS2 active
03
SOS active
04
SLS active
07
Internal event
09
Active SLS stage bit 0
10
Active SLS stage bit 1
11
SOS selected
12
SDI pos active
13
SDI neg active
15
SSM (speed below limit value)
Notice:
Re bit 07:
The signal state behaves in an opposite way to the PROFIsafe Standard.
Note:
This parameter is only supplied with actual values in the case of Safety Integrated Extended Functions. For Safety
Integrated Basic Functions (SBC, SS1, STO), the value is equal to zero.
Re bit 07:
An internal event is displayed if a STOP A ... F is active.
r9723.0...16
CO/BO: SI Motion diagnostic signals integrated in the drive / SI Mtn integ diag
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Displays the diagnostic signals for safety-relevant motion monitoring functions integrated in the drive.
Bit field:
Bit
Signal name
00
Forced checking procedure required
01
For ESR, STOP F and subsequent stop B is
active
02
Communication failure
03
Actual value sensing supplies valid value
04
Encoderless act val sensing acc to tech-
nique for U/f control
16
SAM/SBR active
Note:
ESR: Extended Stop and Retract
SAM: Safe Acceleration Monitor (safe acceleration monitoring)
SBR: Safe Brake Ramp (safe brake ramp monitoring)
1-592
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
No
Set
Set
Yes
Yes
Yes
Yes
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: 2840, 2855
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
-
No
-
No
-
No
-
No
-
Yes
-
Not set
-
Not set
-
No
-
No
2861
No
2861
No
2860
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
-
No
-
No
-
No
-
No
-
No
-

Hide quick links: