p4812
Function generator physical address / FG phys address
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: Trace and function generator
Not for motor type: -
Min
0
Description:
Sets the physical address where the function generator is to be connected.
Dependency:
Only effective when p4810 = 99.
p4813
Function generator physical address reference value / FG phys addr ref
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN
P-Group: Trace and function generator
Not for motor type: -
Min
1.00
Description:
Sets the reference value for 100 % for referred inputs.
Dependency:
Only effective when p4810 = 99.
p4815[0...2]
Function generator drive number / FG drive number
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN
P-Group: Trace and function generator
Not for motor type: -
Min
0
Description:
Selects the required drive where the function generator is to be connected.
Index:
[0] = First drive for connection
[1] = Second drive for connection
[2] = Third drive for connection
Dependency:
Only effective when p4810 = 1, 2, 3, 4 or 5.
Note:
For the function generator, only type SERVO, VECTOR or DC_CTRL type drives can be used.
p4816
Function generator output signal integer number scaling / FG outp integ scal
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Integer32
CU_S110-PN
P-Group: -
Not for motor type: -
Min
-2147483648
Description:
Sets the scaling for the integer number of the output signal for the function generator.
Dependency:
Refer to: r4805, r4817
Note:
The parameter can only be changed in the following operating states:
r4805 = 0, 4, 6
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Connection at connector output r4818
Connection at current setpoint after filter and r4818
Connection as disturbing torque and r4818
Connection at speed setpoint after filter and r4818
Connection at current setpoint before filter and r4818
Connection at speed setpoint before filter and r4818
Connection for free measurement function r4818 and r4834
Connection at physical address and r4818
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
4294967295
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1000000.00
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
65535
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
2147483647
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
1.00
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting