Siemens SINAMICS S110 List Manual page 449

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

16:
20:
29:
Note:
SMI: SINAMICS Sensor Module Integrated
p4692 = 10: Automatic on successful completion of backup procedure.
p4692 = 13, 16, 20, 29: Error vales if the procedure could not be executed successfully.
The procedure must be repeated if the data save operation was interrupted (e.g. if the power supply voltage failed).
Help for error value = 13:
- Use a memory card with more memory space.
Help for error value = 16:
- check the DRIVE-CLiQ connection.
Help for error value = 20:
- Use an SMI card that is not blank.
Help for error value = 29:
- Check and correct the target and actual topologies for the SMIs.
- Repeat the save procedure.
p4693[0...1]
SMI spare part data backup directory/storage location / SMI bkup dir/loc
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
0
Description:
Sets the directory and storage location for downloading and saving data.
Example:
The SMI has the component number 5 and the SMI data (motor/encoder data) is to be stored in subdirectory C205.
--> p4690 = 5, p4693[0] = 205, p4691 = 1
Index:
[0] = Subdirectory selection
[1] = Memory location
Dependency:
Refer to: p4691, r4694
Notice:
If p4693[0] is not equal to 0 and p4693[0] is not equal to p4690, the following applies:
- Only a number >= 200 may be selected for the subdirectory when saving.
- In the case of downloads, a selection for the subdirectory may only be made for an SMI/DQI with a component
number >= 200 (preliminary component number) (p4690 >= 200).
Note:
SMI: SINAMICS Sensor Module Integrated
Re index 0:
This index is used to select the subdirectory for saving and downloading data; in the event of access to r4694 the
motor order number (MLFB) of the corresponding data backup is displayed.
Re index 1:
This index is used to set the memory location for the subdirectory for downloading data and the display of the motor
order number (MLFB).
0: Non-volatile device memory
1: Memory card (optional)
r4694[0...19]
SMI spare part data backup motor order number / SMI dat_bkup MLFB
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned8
CU_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the motor order number (MLFB) of the data backup selected with p4693.
Dependency:
Refer to: p4691, p4692
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Transfer fault during data backup
Component does not contain any data
Not all components from target topology saved
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
399
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
1-449