p9552
SI Motion transition time STOP C to SOS (processor 1) / SI Mtn t C->SOS P1
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [ms]
Description:
Sets the transition time from STOP C to "Safe Operating Stop" (SOS).
Note:
SOS: Safe Operating Stop
p9553
SI Motion transition time STOP D to SOS (processor 1) / SI Mtn t D->SOS P1
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [ms]
Description:
Sets the transition time from STOP D to "Safe Operating Stop" (SOS).
Note:
SOS: Safe Operating Stop
p9554
SI Motion transition time STOP E to SOS (processor 1) / SI Mtn t E->SOS P1
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [ms]
Description:
Sets the transition time from STOP E to "Safe Operating Stop" (SOS).
Dependency:
Refer to: p9354
Note:
SOS: Safe Operating Stop
p9555
SI Motion transition time STOP F to STOP B (processor 1) / SI Mtn t F->B P1
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [ms]
Description:
Sets the transition time from STOP F to STOP B.
Dependency:
Refer to: C01711
p9556
SI Motion pulse suppression delay time (processor 1) / SI Mtn IL t_del P1
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [ms]
Description:
Sets the delay time for the safe pulse suppression after STOP B.
In the case of encoderless motion monitoring functions with brake ramp monitoring (p9506 = 1), the parameter has
no effect.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
600000.00 [ms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
600000.00 [ms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
600000.00 [ms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
600000.00 [ms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
600000.00 [ms]
Parameter
List of parameters
Access level: 3
Func. diagram: 2825
Unit selection: -
Expert list: 1
Factory setting
100.00 [ms]
Access level: 3
Func. diagram: 2825
Unit selection: -
Expert list: 1
Factory setting
100.00 [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
100.00 [ms]
Access level: 3
Func. diagram: 2825
Unit selection: -
Expert list: 1
Factory setting
0.00 [ms]
Access level: 3
Func. diagram: 2825
Unit selection: -
Expert list: 1
Factory setting
100.00 [ms]