p9580
SI Motion pulse suppression delay bus failure (processor 1) / SI Mtn t to IL P1
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [ms]
Description:
Sets the delay time after which the pulses are safely suppressed after a bus failure.
Dependency:
Refer to: p9561, p9563
p9581
SI Motion brake ramp reference value (processor 1) / SI Mtn ramp ref P1
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
600.0000 [mm/min]
Description:
Sets the reference value to define the brake ramp.
The rate of rise of the brake ramp depends upon p9581 (reference value) and p9583 (monitoring time).
Dependency:
Refer to: p9582, p9583
p9581
SI Motion brake ramp reference value (processor 1) / SI Mtn ramp ref P1
SERVO_S110-CAN
Can be changed: C2(95)
(Safety rot),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Safety Integrated
(Safety rot),
Not for motor type: -
SERVO_S110-PN
(Safety rot)
Min
600.0000 [rpm]
Description:
Sets the reference value to define the brake ramp.
The rate of rise of the brake ramp depends upon p9581 (reference value) and p9583 (monitoring time).
Dependency:
Refer to: p9582, p9583
p9582
SI Motion brake ramp delay time (processor 1) / SI Mtn rp t_del P1
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
10.00 [ms]
Description:
Sets the delay time for monitoring the brake ramp.
Monitoring of the brake ramp starts once the delay time has elapsed.
Dependency:
Refer to: p9581, p9583
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
800.00 [ms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
24000.0000 [mm/min]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
24000.0000 [rpm]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
99000.00 [ms]
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00 [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1500.0000 [mm/min]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1500.0000 [rpm]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
250.00 [ms]
1-581

Hide quick links:

Advertisement

Table of Contents
loading