Siemens SINAMICS S110 List Manual page 612

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
- serial number of the Node Identifier (4 indices)
- index of the component
- order number (8 indices)
- attribute to compare the actual topology and target topology of the component
- communications address
- number of port types
- port type
- number of ports of the port type
- communications address of the associated/linked component
- number of the associated/linked port
- communications address of the associated/linked component
- number of the associated port, etc.
Data on the next component:
- etc.
Dependency:
Refer to: r9900
Note:
Only for internal Siemens use.
The parameter is not displayed for the STARTER commissioning software.
p9902
Target topology number of indices / TargetTopo indices
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN
P-Group: Topology
Not for motor type: -
Min
1
Description:
Sets the number of target topology indices.
Dependency:
Refer to: p9903
Note:
Only for internal Siemens use.
The parameter is not displayed for the STARTER commissioning software.
p9903[0...n]
Target topology / Target topo
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN
P-Group: Topology
Not for motor type: -
Min
0000 hex
Description:
Sets the target topology of the drive unit.
The target topology is sub-divided into several sections. Each of the following data is saved under an index.
General data on the topology:
- version
- attribute to compare the actual topology and target topology
- number of components
Data on a component:
- type component of the Node Identifier of the component
- number of DRIVE-CLiQ sockets in the Node Identifier
- manufacturer and version of the Node Identifier
- serial number of the Node Identifier (4 indices)
- index of the component
- order number (8 indices)
- attribute to compare the actual topology and target topology of the component
- component number
- number of port types
1-612
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
65535
Calculated: -
Dynamic index: p9902
Units group: -
Scaling: -
Max
FFFF hex
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
1
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0000 hex

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents