Siemens SINAMICS S110 List Manual page 444

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
p4676[0...n]
Analog sensor range limit threshold / Ana_sens lim thr
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: -
Not for motor type: -
Min
0.0 [%]
Description:
Sets the threshold for limit monitoring of the absolute actual value on the analog sensor.
If this threshold is overshot by the actual value of a channel, a corresponding fault/alarm (p4670.9) is output.
Dependency:
Refer to: p4673, p4675
p4677[0...n]
Analog sensor LVDT configuration / Ana_sens LVDT conf
SERVO_S110-CAN,
Can be changed: C2(4)
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Sets the configuration for LVDT mode on the analog sensor.
Bit field:
Bit
Signal name
00
LVDT ON
01
Track B excitation
02
Fixed value amplitude
03
Fixed value amplitude and phase
p4678[0...n]
Analog sensor LVDT ratio / An_sens LVDT ratio
SERVO_S110-CAN,
Can be changed: C2(4)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
0.00 [%]
Description:
Sets the ratio for the LVDT sensor.
p4679[0...n]
Analog sensor LVDT phase / An_sens LVDT ph
SERVO_S110-CAN,
Can be changed: C2(4), T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
-360.00 [°]
Description:
Sets the phase for the LVDT sensor.
p4680[0...n]
Zero mark monitoring tolerance permissible / ZM_monit tol perm
SERVO_S110-CAN,
Can be changed: C2(4)
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the permissible tolerance in encoder pulses for the zero mark distance in the context of zero mark monitoring.
Causes fault F3x100 to appear less frequently.
1-444
Calculated: -
Dynamic index: EDS, p0140
Units group: -
Scaling: -
Max
100.0 [%]
Calculated: -
Dynamic index: EDS, p0140
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Calculated: -
Dynamic index: EDS, p0140
Units group: -
Scaling: -
Max
200.00 [%]
Calculated: -
Dynamic index: EDS, p0140
Units group: -
Scaling: -
Max
360.00 [°]
Calculated: -
Dynamic index: EDS, p0140
Units group: -
Scaling: -
Max
1000
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
100.0 [%]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 bin
0 signal
FP
No
-
No
-
No
-
No
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
50.00 [%]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00 [°]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents