Siemens SINAMICS S110 List Manual page 639

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Bit 5 = SDI_pos_active
Bit 6 = SDI_neg_active
Bit field:
Bit
Signal name
00
Power_removed
01
SS1_active
02
SS2_active
03
SOS_active
04
SLS_active
05
SDI_pos_active
06
SDI_neg_active
Note:
Bit = 0 signal --> not selected
Bit = 1 signal --> selected
The selected signals (high-active) are OR'ed The result of the logic operation results in the status "Safe State".
p10140
SI F-DI input mode (processor 2) / SI F-DI mode P2
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Sets the input mode for the safety digital inputs (F-DI).
Bit field:
Bit
Signal name
00
F-DI 1 (X130.2)
01
F-DI 2 (X130.5)
02
F-DI 3 (X131.2)
Note:
Only an NC contact can be connected for the safety digital inputs not listed.
p10142[0...5]
SI F-DO 0 signal sources (processor 2) / SI F-DO 0 S_src P2
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the signal sources for F-DO 0 (X131.6).
The 6 signal sources in p10142[0...5] are AND'ed and the result is output at F-DO 0.
Value:
0:
1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
Index:
[0] = AND logic operation input 1
[1] = AND logic operation input 2
[2] = AND logic operation input 3
[3] = AND logic operation input 4
[4] = AND logic operation input 5
[5] = AND logic operation input 6
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
No function
STO active
SS1 active
SS2 active
SOS active
SLS active
SSM feedback signal active
Safe state
SOS selected
Internal event
Active SLS stage bit 0
Active SLS stage bit 1
SDI positive active
SDI negative active
1 signal
Selected
Selected
Selected
Selected
Selected
Selected
Selected
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
NO contact
NO contact
NO contact
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
13
Parameter
List of parameters
0 signal
FP
Not selected
-
Not selected
-
Not selected
-
Not selected
-
Not selected
-
Not selected
-
Not selected
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 bin
0 signal
FP
NC contact
2850
NC contact
2850
NC contact
2850
Access level: 3
Func. diagram: 2857
Unit selection: -
Expert list: 1
Factory setting
0
1-639

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents