p9589
SI Motion voltage tolerance acceleration (processor 1) / SI Mtn U tol P1
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
10.00 [%]
Description:
Sets the voltage tolerance for suppressing acceleration peaks.
Increasing this percentage value means that voltage peaks will need to have a higher amplitude during acceleration
procedures if they are not to affect actual value sensing.
- The value must be increased if C01711 has occurred with message value 1043.
- The value must be lowered if acceleration procedures have led to an excessive Safety actual velocity.
Dependency:
Refer to: C01711
Note:
This parameter is only effective for encoderless actual value sensing (p9306/p9506 = 1).
r9590[0...3]
SI Motion version safety motion monitoring (processor 1) / SI Mtn version P1
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Displays the Safety Integrated version for the safe monitoring functions.
Index:
[0] = Safety Version (major release)
[1] = Safety Version (minor release)
[2] = Safety Version (baselevel or patch)
[3] = Safety Version (hotfix)
Dependency:
Refer to: r9770, r9890
Note:
Example:
r9590[0] = 2, r9590[1] = 60, r9590[2] = 1, r9590[3] = 0 --> SI Motion version V02.60.01.00
p9601
SI enable, functions integrated in the drive (processor 1) / SI enable fct P1
SERVO_S110-CAN
Can be changed: C2(95)
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Sets the enable signals for safety functions on processor 1 that are integrated in the drive.
Bit field:
Bit
Signal name
00
STO (SH) via terminals (Control Unit)
enable
02
Motion monitoring functions integr. in the
drive (Control Unit)
Dependency:
Refer to: r9771, p9801
Note:
STO: Safe Torque Off
A change only becomes effective after a POWER ON.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1000.00 [%]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Enable
Enable
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
100.00 [%]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 bin
0 signal
FP
Inhibit
2810
Inhibit
-