p8603
CAN COB-ID Emergency Message / COB-ID EMCY Msg
CU_S110-CAN
Can be changed: T
Data type: Unsigned32
P-Group: Communications
Not for motor type: -
Min
0000 hex
Description:
Sets the COB-ID for the emergency message (error telegram).
It corresponds to the CANopen objects:
- 1014 hex: COB-ID
Note:
If, when downloading, the pre-set value 0 is downloaded, then the CANopen pre-set value 80 hex + Node-ID is
automatically set.
Online, the value 0 is rejected as, according to the CANopen Standard, COB-ID 0 is not permitted here.
The changeover of the node ID using the hardware switch at the Control Unit or per software has no effect on the
COB-ID EMCY. The saved value remains effective.
p8604[0...1]
CAN node guarding / Node guarding
CU_S110-CAN
Can be changed: T
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the node guarding parameter for the following CANopen objects:
- 100C hex: Guard Time
- 100D hex: Life Time Factor
The life time is derived by multiplying guard time by the life time factor.
Index:
[0] = Time interval [ms] for new node guarding telegram
[1] = Factor for failure of the node guarding telegram
Dependency:
Only adjustable if heartbeat time = 0 (heartbeat is disabled).
Refer to: p8606
Note:
For p8604[0] = 0 and/or p8604[1] = 0, the node guarding protocol is not used.
Either node guarding or heartbeat can be used.
p8606
CAN Producer Heartbeat Time / Prod Heartb Time
CU_S110-CAN
Can be changed: T
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
0 [ms]
Description:
Sets the time [ms] to cyclically send heartbeat telegrams.
The smallest cycle time is 100 ms.
When a 0 is written, then heartbeat telegrams are not sent.
Dependency:
Only adjustable if guard time = 0 (node guarding disabled).
Refer to: p8604
Note:
Corresponds to the CANopen object 1017 hex.
Either node guarding or heartbeat can be used.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
FFFF FFFF hex
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
65535
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
65535 [ms]
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 hex
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0 [ms]
1-499