Signal targets for STW2 in Interface Mode SIMODRIVE 611 universal (p2038 = 1)
Signal
Meaning
STW2.0
Drive data set selection DDS, bit 0
STW2.1
Reserved
STW2.2
Reserved
STW2.3
Reserved
STW2.4
1 = Bypass ramp-function generator
STW2.5
Reserved
STW2.6
1 = Integrator inhibit, speed controller
STW2.7
1 = Parking axis selection
STW2.8
1 = Traverse to fixed endstop
STW2.9
Reserved
STW2.10
Reserved
STW2.11
= Motor changeover, feedback signal
STW2.12
Master sign-of-life, bit 0
STW2.13
Master sign-of-life, bit 1
STW2.14
Master sign-of-life, bit 2
STW2.15
Master sign-of-life, bit 3
<1> Used in telegrams 2, 3, 4, 102, 103.
<2> For a 1 signal, the integral component of the speed controller is cleared and the integrator is inhibited.
1
2
DO: SERVO
PROFIdrive - STW2 control word interconnection (p2038 = 1)
Interconnection
p0820[0] = r2093.0
<3>
p1122[0] = r2093.4
p1477[0] = r2093.6
<2>
p0897 = r2093.7
p1545[0] = r2093.8
p0828[0] = r2093.11
p2045 = r2050[3]
<3> Only if the function module "extended setpoint channel" is active (r0108.8 = 1).
3
4
[Function diagram]
[Function diagram]
parameters
internal control word
signal target
-
[8565]
-
-
-
-
-
-
-
[3060] [3070]
-
-
-
[5040] [5210]
-
[2520.2]
[8012]
-
-
-
-
-
-
[2410]
5
6
fp_2445_98_eng.vsd
25.01.10 V04.04.00
PROFIdrive sampling time
<1>
Refer to [1020.7]
Inverted
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
7
8
Function diagram
- 2445 -
SINAMICS S110