p3295
Variable signaling function threshold value / Var sig thresh_val
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: -
Not for motor type: -
Min
-340.28235E36
Description:
Sets the threshold value for the variable signaling function.
p3296
Variable signaling function hysteresis / Var sig hyst
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: -
Not for motor type: -
Min
0.000
Description:
Sets the hysteresis for the variable signaling function.
p3297
Variable signaling function pickup delay / Var sig t_pickup
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: -
Not for motor type: -
Min
0 [ms]
Description:
Sets the pickup delay for the variable signaling function.
Notice:
Values that do not comply with the following condition are treated just like value 0:
Pickup delay (p3297) >= sampling time (p3299)
Note:
For a value of 0, the pickup delay is disabled.
The output signal is set if the condition for the 1 signal is fulfilled for longer than the selected time.
p3298
Variable signaling function dropout delay / Var sig t_dropout
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: -
Not for motor type: -
Min
0 [ms]
Description:
Sets the dropout delay for the variable signaling function.
Notice:
Values that do not comply with the following condition are treated just like value 0:
Dropout delay (p3298) >= sampling time (p3299)
Note:
For a value of 0, the dropout delay is disabled.
The output signal is reset if the condition for the 0 signal is fulfilled for longer than the selected time.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
340.28235E36
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
340.28235E36
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
10000 [ms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
10000 [ms]
Parameter
List of parameters
Access level: 3
Func. diagram: 5301
Unit selection: -
Expert list: 1
Factory setting
0.000
Access level: 3
Func. diagram: 5301
Unit selection: -
Expert list: 1
Factory setting
0.000
Access level: 3
Func. diagram: 5301
Unit selection: -
Expert list: 1
Factory setting
0 [ms]
Access level: 3
Func. diagram: 5301
Unit selection: -
Expert list: 1
Factory setting
0 [ms]
1-433