Siemens SINAMICS S110 List Manual page 479

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

- p3981 (acknowledge fault, drive object)
- p7760 (adjustable parameters write protection)
p7820
DRIVE-CLiQ component component number / DLQ comp_no
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the component number of the DRIVE-CLiQ component whose parameters are to be accessed.
Dependency:
Refer to: p7821, p7822, r7823
p7821
DRIVE-CLiQ component parameter number / DLQ para_no
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the parameter number to access a parameter of a DRIVE-CLiQ component.
Dependency:
Refer to: p7820, p7822, r7823
p7822
DRIVE-CLiQ component parameter index / DLQ para_index
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the parameter index to access a parameter of a DRIVE-CLiQ component.
Dependency:
Refer to: p7820, p7821, r7823
r7823
DRIVE-CLiQ component read parameter value / Read DLQ value
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the parameter value read from the DRIVE-CLiQ component.
Dependency:
Refer to: p7820, p7821, p7822
r7825[0...6]
DRIVE-CLiQ component versions / DLQ version
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the firmware and EPROM versions of the DRIVE-CLiQ component selected using p7828[1].
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
65535
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
65535
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
65535
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Parameter
List of parameters
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
1-479