Siemens SINAMICS S110 List Manual page 577

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Dependency:
Refer to: p9556
p9560
SI Motion pulse suppression shutdown speed (Control Unit) / SI Mtn IL n_shutCU
SERVO_S110-CAN
Can be changed: C2(95)
(Safety rot),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Safety Integrated
(Safety rot),
Not for motor type: -
SERVO_S110-PN
(Safety rot)
Min
0.00 [rpm]
Description:
Sets the shutdown speed for the pulse suppression.
Below this speed "standstill" is assumed and for STOP B, the pulses are suppressed by changing to STOP A).
Dependency:
Refer to: p9556
p9561
SI Motion SLS stop response (processor 1) / SI Mtn SLS resp
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the stop response for the function "Safely-Limited Speed" (SLS).
This setting applies for all SLS limit values.
An input value of less than 5 signifies personnel protection, from 10 and upwards, machine protection.
This parameter can only be used for ncSI nutzbar, not for dbSI1/2. For motion monitoring functions integrated in the
drive (dbSI1/2) only the value 5 is permissible; all other settings result in fault F01711 or F30711 with fault value 44.
Value:
0:
1:
2:
3:
4:
5:
10:
11:
12:
13:
14:
Dependency:
Refer to: p9531, p9563, p9580
Note:
SLS: Safely-Limited Speed
p9562
SI Motion SLP stop response (processor 1) / SI Mtn SLP resp
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
2
Description:
Sets the stop response for the function "Safely-Limited Position" (SLP).
Value:
2:
3:
4:
Dependency:
Refer to: p9534, p9535
Note:
SLP: Safely-Limited Position
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
STOP A
STOP B
STOP C
STOP D
STOP E
Sets the stop response via p9563 (SLS-specific)
STOP A with delayed pulse suppression when the bus fails
STOP B with delayed pulse suppression when the bus fails
STOP C with delayed pulse suppression when the bus fails
STOP D with delayed pulse suppression when the bus fails
STOP E with delayed pulse suppression when the bus fails
STOP C
STOP D
STOP E
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
6000.00 [rpm]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
14
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
4
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00 [rpm]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
5
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
2
1-577