Siemens SINAMICS S110 List Manual page 593

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

r9724
SI Motion crosswise comparison clock cycle / SI Mtn CDC clk cyc
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
- [ms]
Description:
Displays the crosswise comparison clock cycle.
The value indicates the clock cycle time with which each individual CDC value is compared between the two moni-
toring channels.
Dependency:
Refer to: p9500
Note:
Crosswise comparison clock cycle = monitoring clock cycle (p9500) * number of data to be crosswise compared
CDC: Crosswise Data Check
r9725[0...2]
SI Motion, diagnostics STOP F / SI Mtn Diag STOP F
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Re index 0:
Displays the message value that resulted in the STOP F on the drive.
Value = 0:
The Control Unit signaled a STOP F.
Value = 1 ... 999:
Number of the incorrect date in the crosswise data comparison between the monitoring channels.
Value >= 1000:
Additional diagnostic values of the drive.
Re index 1:
Displays the value of the Control Unit that resulted in the STOP F.
Re index 2:
Displays the value from the second channel that resulted in the STOP F.
Index:
[0] = Message value for CDC
[1] = Control Unit CDC act value
[2] = Components CDC act val
Dependency:
Refer to: C01711
Note:
The significance of the individual message values is described in message C01711.
CDC: Crosswise Data Check
p9726
SI Motion, user agreement selection/de-selection / SI Mtn UserAgr sel
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0000 hex
Description:
Setting to select and de-select the user agreement.
Value:
0:
172:
Dependency:
Refer to: r9727
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
[00 hex] De-select user agreement
[AC hex] Select user agreement
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [ms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
00AC hex
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 hex