Parameter
Parameters for data sets
p1141[0...n]
p1142[0...n]
p1143[0...n]
p1144[0...n]
p1155[0...n]
p1160[0...n]
p1230[0...n]
p1235[0...n]
p1430[0...n]
p1455[0...n]
p1466[0...n]
p1476[0...n]
p1477[0...n]
p1478[0...n]
p1497[0...n]
p1501[0...n]
p1502[0...n]
p1511[0...n]
p1512[0...n]
p1513[0...n]
p1522[0...n]
p1523[0...n]
p1528[0...n]
p1529[0...n]
p1542[0...n]
p1545[0...n]
p1550[0...n]
p1551[0...n]
p1552[0...n]
p1554[0...n]
p1569[0...n]
p2103[0...n]
p2104[0...n]
p2105[0...n]
p2106[0...n]
p2107[0...n]
p2108[0...n]
p2112[0...n]
p2116[0...n]
p2117[0...n]
p2144[0...n]
p2148[0...n]
p2151[0...n]
p2154[0...n]
p2200[0...n]
p2220[0...n]
p2221[0...n]
p2222[0...n]
p2223[0...n]
p2235[0...n]
p2236[0...n]
p2253[0...n]
p2254[0...n]
1-734
BI: Continue ramp-function generator/freeze ramp-function generator / Continue RFG
BI: Enable setpoint/inhibit setpoint / Setpoint enable
BI: Ramp-function generator, accept setting value / RFG accept set v
CI: Ramp-function generator setting value / RFG setting value
CI: Speed controller speed setpoint 1 / n_ctrl n_set 1
CI: Speed controller speed setpoint 2 / n_ctrl n_set 2
BI: Armature short-circuit / DC braking activation / ASC/DCBRK act
BI: External armature short-circuit, contactor feedback signal / ASC ext feedback
CI: Speed pre-control / n_prectrl
CI: Speed controller P gain adaptation signal / n_ctrl Adpt_sig Kp
CI: Speed controller P-gain scaling / n_ctrl Kp scal
BI: Speed controller hold integrator / n_ctrl integ stop
BI: Speed controller set integrator value / n_ctrl integ set
CI: Speed controller integrator setting value / n_ctr integ_setVal
CI: Moment of inertia, scaling / M_mom inert scal
BI: Change over between closed-loop speed/torque control / Changeov n/M_ctrl
BI: Freeze moment of inertia estimator / J_estim freeze
CI: Supplementary torque 1 / M_suppl 1
CI: Supplementary torque 1 scaling / M_suppl 1 scal
CI: Supplementary torque 2 / M_suppl 2
CI: Torque limit upper/motoring / M_max upper/mot
CI: Torque limit lower/regenerative / M_max lower/regen
CI: Torque limit upper/motoring scaling / M_max up/mot scal
CI: Torque limit lower/regenerative scaling / M_max low/gen scal
CI: Travel to fixed stop torque reduction / TfS M_red
BI: Activates travel to a fixed stop / TfS activation
BI: Transfer actual torque as torque offset / Accept act torque
BI: Torque limit variable/fixed signal source / M_lim var/fixS_src
CI: Torque limit upper scaling without offset / M_max up w/o offs
CI: Torque limit lower scaling without offset / M_max low w/o offs
CI: Supplementary torque 3 / M_suppl 3
BI: 1. Acknowledge faults / 1. Acknowledge
BI: 2. Acknowledge faults / 2. Acknowledge
BI: 3. Acknowledge faults / 3. Acknowledge
BI: External fault 1 / External fault 1
BI: External fault 2 / External fault 2
BI: External fault 3 / External fault 3
BI: External alarm 1 / External alarm 1
BI: External alarm 2 / External alarm 2
BI: External alarm 3 / External alarm 3
BI: Motor stall monitoring enable (negated) / Mot stall enab neg
BI: RFG active / RFG active
CI: Speed setpoint for messages/signals / n_set for msg
CI: Speed setpoint 2 / n_set 2
BI: Technology controller enable / Tec_ctrl enable
BI: Technology controller fixed value selection bit 0 / Tec_ctrl sel bit 0
BI: Technology controller fixed value selection bit 1 / Tec_ctrl sel bit 1
BI: Technology controller fixed value selection bit 2 / Tec_ctrl sel bit 2
BI: Technology controller fixed value selection bit 3 / Tec_ctrl sel bit 3
BI: Technology controller motorized potentiometer raise setpoint / Tec_ctrl mop raise
BI: Technology controller motorized potentiometer lower setpoint / Tec_ctrl mop lower
CI: Technology controller setpoint 1 / Tec_ctrl setp 1
CI: Technology controller setpoint 2 / Tec_ctrl setp 2
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3