Siemens SINAMICS S110 List Manual page 705

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

p20198[0...3]
BI: DFR 0 inputs / DFR 0 inputs
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Unsigned32 / Binary
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-
Description:
Sets the signal source for trigger input I, D input D, set input S, and reset input R of instance DFR 0 of the D flipflop.
Index:
[0] = Trigger input I
[1] = D input D
[2] = Set S
[3] = Reset R
r20199
BO: DFR 0 output Q / DFR 0 output Q
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-
Description:
Display parameter for output Q of instance DFR 0 of the D flipflop.
r20200
BO: DFR 0 inverted output QN / DFR 0 inv outp QN
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-
Description:
Display parameter for the inverted output QN of instance DFR 0 of the D flipflop.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Parameter
List of parameters
Access level: 1
Func. diagram: 7240
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 7240
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 1
Func. diagram: 7240
Unit selection: -
Expert list: 1
Factory setting
-
1-705