Siemens SINAMICS S110 List Manual page 943

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Rated motor temperature rise
Calculated motor temperatures
192 ms
Mot T_environment
p0625[M]
Mot T_on iron
p0626[M]
Thermal
3-mass-model
Mot T_on stator
(for induction motors
p0627[M]
only)
Mot T_on rotor
p0628[M]
Model tracking
Mot temp_sensor
p0600[M]
Nur
bei
0
KTY
from encoder 1
1
[4704.8]
from Motor Modules
or CUA31
11
Temperature sensor
via BICO connection
10
<1> For KTY and PTC, the value p0606 = 0 has a different meaning:
KTY: 0
The output of the timer is always switched out (logical 0)
PTC: 0
Delay time = 0 s
<2> As for the switch-in delay, refer to [1024]. p0607 = 0 suppresses fault F07016.
<3> For KTY and "No sensor", temperature as defined in the model.
<4> P0606 does not work for alarms via p0616.
<5> The relevant rated response temperature in °C depends on the temperature sensor chosen by the motor manufacturer.
1
2
DO: SERVO
Signals and monitoring functions - Thermal monitoring, motor
MotTMod T_environ
r0630[M]
MotTMod T_iron
r0631[M]
MotTMod T_copper
r0632[M]
MotTMod T_rotor
r0633[M]
Mot temp_sensortyp
p0601[M]
0 = No sensor
1 = PTC alarm and time
2 = KTY84
3 = KTY84 & PTC, for
encoder only
3
4
T_mot gemessen
r0035
Mot_temp fault thresh
p0605[M]
1
&
0
KTY sensor type
(threshold not applicable for PTC)
Mot_temp AlrmThresh
p0604[M]
Mot temp alarm 1
p0616[M]
M I N
p0606[M]
1650
<5>
<1>
<4>
KTY
PTC
Sensor type
T
0
<3>
1
0
Mot temp_sens time
p0607[M]
-140 °C
250 °C
<2>
T
0
5
6
Function diagram
fp_8016_98_eng.vsd
SINAMICS S110
16.11.10 V04.04.00
1.00 s
F07011
1
"Motor overtemperature"
1
r2135.12
[2548.2]
A07910
"Motor overtemperature"
1
r2135.14
[2548.2]
A07016
"Motor temperature
sensor fault, fault"
A07015
"Motor temperature
sensor fault alarm"
A07820 "Temperature sensor not connected"
7
8
- 8016 -

Hide quick links:

Advertisement

Table of Contents
loading