p10040
SI F-DI input mode / SI F-DI inp_mode
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Sets the input mode for the safety digital inputs (F-DI).
Bit field:
Bit
Signal name
00
F-DI 1 (X130.2)
01
F-DI 2 (X130.5)
02
F-DI 3 (X131.2)
Note:
Only an NC contact can be connected for the safety digital inputs not listed.
p10042[0...5]
SI F-DO 0 signal sources / SI F-DO 0 S_src
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the signal sources for F-DO 0 (X131.5).
The 6 signal sources in p10042[0...5] are AND'ed and the result is output at F-DO 0.
Value:
0:
1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
Index:
[0] = AND logic operation input 1
[1] = AND logic operation input 2
[2] = AND logic operation input 3
[3] = AND logic operation input 4
[4] = AND logic operation input 5
[5] = AND logic operation input 6
Note:
F-DO: Failsafe Digital Output
p10046
SI F-DO feedback signal input activation / SI F-DO FS act
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Activates the readback input for the safety digital output (F-DO)
The test mode for the particular safety digital output is set in p10047.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
No function
STO active
SS1 active
SS2 active
SOS active
SLS active
SSM feedback signal active
Safe state
SOS selected
Internal event
Active SLS stage bit 0
Active SLS stage bit 1
SDI positive active
SDI negative active
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
NO contact
NO contact
NO contact
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
13
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 bin
0 signal
FP
NC contact
2850
NC contact
2850
NC contact
2850
Access level: 3
Func. diagram: 2857
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 bin
1-631