Faults and alarms
Overview of faults and alarms
3.1.2
Explanation of the list of faults and alarms
The data in the following example has been chosen at random. The information
listed below is the maximum amount of information that a description can contain:
Some of the information is optional.
The list of faults and alarms (See Chapter 3.2) is structured as follows:
- - - - - - - - - - - - - - - - - - - - - - - - - Start of example - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Axxxxx (F, N)
Fault location (optional): Name
Message value:
Component number: %1, cause of fault: %2
Drive object:
List of objects.
Reaction:
NONE
Acknowledge:
NONE
Cause:
Description of possible causes
Fault value (r0949, interpret format): or alarm value (r2124, interpret format): (optional)
Information about fault or alarm values (optional)
Remedy:
Description of possible remedies
Reaction upon F:
A_INFEED: OFF2 (OFF1, NONE)
SERVO: NONE (OFF1, OFF2, OFF3)
VECTOR: NONE (OFF1, OFF2, OFF3)
Acknowl. upon F:
IMMEDIATELY (POWER ON)
Reaction upon N:
NONE
Acknowl. upon N:
NONE
- - - - - - - - - - - - - - - - - - - - - - - - - End of example - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Axxxxx
Alarm xxxxx
Axxxxx (F, N) Alarm xxxxx (message type can be changed to F or N)
Fxxxxx
Fault xxxxx
Fxxxxx (A, N) Fault xxxxx (report type can be changed to A or N)
Nxxxxx
No message
Nxxxxx (A)
No message (message type can be changed to A)
Cxxxxx
Safety message (separate message buffer)
A message comprises a letter followed by the relevant number.
The meaning of the letters is as follows:
• A means "Alarm".
• F means "Fault".
• N means "No message" or "Internal message".
• C means "Safety message"
The optional parentheses indicate whether the type specified for this message
can be changed and which message types can be adjusted via parameters
(p2118, p2119).
Information on reaction and acknowledgment is specified independently for a
message with an adjustable message type (e.g. reaction to F, acknowledgment
for F).
3-970