Parameter
List of parameters
Bit field:
Bit
Signal name
00
Test F-DO 0
Dependency:
Refer to: p10001, p10003, p10007, p10047
Note:
The test stop is only performed if the safety output of the Control Unit is being used (see p10042).
p10047
SI F-DO test stop mode / SI F-DO test mode
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0001 bin
Description:
Sets the test stop mode for the safety digital output (F-DO)
Value:
1:
2:
3:
Dependency:
Refer to: p10001, p10003, p10007, p10046
Note:
The test stop is only performed if the safety output is being used (see p10042).
r10049
SI F-DI monitoring status (processor 1) / SI F-DI status P1
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Displays the monitoring status of the fail-safe digital inputs (F-DI).
The F-DIs that are being used by the Safety Integrated functions are displayed.
If the module used has fewer than 3 F-DIs, "Freely available" is displayed for the F-DIs which are not in use.
Bit field:
Bit
Signal name
00
F-DI 0
01
F-DI 1
02
F-DI 2
Dependency:
p10006 / p10106
p10022 / p10122
p10023 / p10123
p10024 / p10124
p10025 / p10125
p10026 / p10126
p10027 / p10127
p10028 / p10128
p10030 / p10130
p10031 / p10131
p10036 / p10136
p10050 / p10150
Refer to: r10149
1-632
Test mode 1 evaluation of int. diagnostic signal (passive load)
Test mode 2 read back F-DO in DI (relay circuit)
Test mode 3 read back F-DO in DI (actuator with feedback signal)
1 signal
Test active
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
0011 bin
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Safety monitored
Safety monitored
Safety monitored
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
0 signal
FP
No test
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0010 bin
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
Freely available
-
Freely available
-
Freely available
-

Hide quick links: