Siemens SINAMICS S110 List Manual page 526

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
p8923[0...3]
PN Subnet Mask of Station / PN Subnet Mask
CU_S110-PN
Can be changed: U, T
Data type: Unsigned8
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the subnet mask for the onboard PROFINET interface on the Control Unit.
The active subnet mask is displayed in r8933.
Note:
The interface configuration (p8920 and following) is activated with p8925 = 1.
The parameter is not influenced by setting the factory setting.
p8925
PN interface configuration / PN IF config
CU_S110-PN
Can be changed: U, T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to control the configuration for the onboard PROFINET interface on the Control Unit.
p8925 is automatically set to 0 at the end of the operation.
Value:
0:
1:
2:
3:
Note:
Re p8925 = 1:
The interface configuration (p8920 and following) is activated.
Re p8925 = 2:
The interface configuration (p8920 and following) is activated and saved to non-volatile memory.
Re p8925 = 3:
Restores all memory locations for the interface configuration to the factory settings.
The factory settings for the interface configuration are loaded on activation (p8925 = 1) or at the next POWER ON.
p8929
PN remote controller number / PN rem ctrl num
CU_S110-PN
Can be changed: C1(1)
Data type: Integer16
P-Group: Communications
Not for motor type: -
Min
1
Description:
Sets the number of remote controllers expected for PROFINET onboard.
The "Shared Device" functionality is activated with a value = 2.
The drive is being accessed by two PROFINET controllers simultaneously:
- automation controller (SIMOTION or SIMATIC A-CPU).
- safety controller (SIMATIC F-CPU).
Value:
1:
2:
Notice:
The F CPU may only use PROFIsafe telegrams.
The A CPU must be connected to enable the F CPU to gain access.
Set the value = 1 to commission the F CPU individually.
Note:
A change only becomes effective after POWER ON, reset or download.
1-526
No function
Activate configuration
Activate and save configuration
Delete configuration
Automation or Safety
Automation and Safety
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
255
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
2
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1