Parameter
List of parameters
p9386
SI Motion delay time of the evaluation sensorless (processor 2) / SI Mtn t_del SL MM
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
5.00 [ms]
Description:
Sets the evaluation delay for encoderless actual value sensing after pulse enable.
The value should be greater than or equal to the motor magnetizing time.
Dependency:
Refer to: C01711
p9387
SI Motion act val sensing sensorless filter time (processor 2) / SI Mtn SL filt P2
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [µs]
Description:
Sets the filter time for smoothing the actual value with sensorless actual value sensing.
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
This parameter is only effective for encoderless actual value sensing (p9306/p9506 = 1).
p9388
SI Motion act val sensing sensorless min current (processor 2) / SI Mtn SL I_min P2
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [%]
Description:
Sets the minimum current for encoderless actual value sensing in reference to 10 mA (i.e. when 1 % = 10 mA).
- The value must be increased if C30711 has occurred with message value 1042.
- The value must be decreased if C30711 has occurred with message value 1041.
Dependency:
Refer to: C30711
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Reducing this percentage value can adversely affect actual value sensing.
Note:
This parameter is only effective for encoderless actual value sensing (p9306/p9506 = 1).
p9389
SI Motion voltage tolerance acceleration (processor 2) / SI Mtn U tol P2
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
10.00 [%]
Description:
Sets the voltage tolerance for suppressing acceleration peaks.
Increasing this percentage value means that voltage peaks will need to have a higher amplitude during acceleration
procedures if they are not to affect actual value sensing.
- The value must be increased if C30711 has occurred with message value 1042.
- The value must be lowered if acceleration procedures have led to an excessive Safety actual velocity.
Dependency:
Refer to: C30711
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
This parameter is only effective for encoderless actual value sensing (p9306/p9506 = 1).
1-548
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1000.00 [ms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
100000.00 [µs]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1000.00 [%]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1000.00 [%]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
100.00 [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
25000.00 [µs]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
10.00 [%]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
100.00 [%]