COB-ID for RPDO 1
p8700[0]
p8701[0]
X126
CAN bus
CANopen
receive telegram
Evaluation
p8702[0]
of the
COB-ID
COB-ID
Object 1
Object 4
p8703[0]
<1> To use automatic BICO interconnection (p8790 = 1), one of the receive words 1-4 must be used as control word 1 (STW1).
<2> Telegram: up to 4 words or 64 bits. The sum of the various objects must not exceed 18 words.
1
2
DO: SERVO
CANopen interface - Receive telegram, Predefined Connection Set (p8744 = 1)
PDO mapping for RPDO 1
p8710[0...3]
<2>
Automatic assignment of the
RPDOs to the receive buffer
RPDO 1
<1>
60400010
p8711[0...3]
RPDO 2
60400010
60FF0020
The assignment is
p8712[0...3]
made from RPDO
1, RPDO 2 ...
RPDO 4 and from
RPDO 3
receiver word 1.
60400010
60710010
Objects available a
multiple number of
p8713[0...3]
times are
marshalled to the
same position in the
RPDO 4
receive buffer.
60400010
60FF0020
60710010
3
4
Receive buffer
PZD receive word 1
r2060[0]
DWORD
PZD receive word 2
r2060[1]
DWORD
PZD receive word 3
r2060[2]
DWORD
PZD receive word 4
r2060[3]
DWORD
PZD receive word 5
r2060[4]
DWORD
PZD receive word 6
r2060[5]
DWORD
PZD receive word 7
r2060[6]
DWORD
PZD receive word 8
r2060[7]
DWORD
PZD receive word 9
r2060[8]
DWORD
PZD receive word 10
r2060[9]
DWORD
PZD receive word 11
r2060[10]
DWORD
PZD receive word 12
r2060[11]
DWORD
PZD receive word 13
r2060[12]
DWORD
PZD receive word 14
r2060[13]
DWORD
PZD receive word 15
r2060[14]
DWORD
PZD receive word 16
r2060[15]
DWORD
PZD receive word 17
r2060[16]
DWORD
PZD receive word 18
5
6
fp_9206_98_eng.vsd
04.11.09 V04.04.00
CAN bus sampling time
Refer to [1020.7]
r2090.0
...
Bit 0
r2090.15
Bit 15
r2050[0]
r2091.0
...
Bit 0
r2091.15
Bit 15
r2050[1]
r2092.0
Bit 0
...
r2092.15
Bit 15
r2050[2]
r2093.0
Bit 0
...
r2093.15
Bit 15
r2050[3]
r2050[4]
r2050[5]
r2050[6]
r2050[7]
r2050[8]
r2050[9]
r2050[10]
r2050[11]
r2050[12]
r2050[13]
r2050[14]
r2050[15]
r2050[16]
r2050[17]
RPDO: Receive Process Data Object