Parameter
List of parameters
Index:
[0] = Reserved
[1] = Computing time utilization
[2] = Reserved
[3] = Reserved
[4] = Reserved
[5] = Largest total utilization
[6] = Reserved
[7] = Reserved
Dependency:
Refer to: r9979, r9980
Refer to: F01054, F01205
Note:
Re index 1:
The value shows the total computing time load of the system.
Re index 5:
The total utilization is determined using all sampling times used. The largest total utilization is mapped here. The
sampling time with the largest total utilization is displayed in r9979.
Total utilization:
Computing time load of sampling time involved including load from higher-priority sampling times (interrupts).
r9979
Sampling time with largest total utilization / t_sampl lg total
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN
P-Group: -
Not for motor type: -
Min
- [µs]
Description:
Displays the sampling time with the largest total utilization.
Dependency:
Refer to: r7901, r9976
Refer to: F01054
Note:
The largest total utilization is displayed in r9976[5].
Total utilization:
Computing time load of sampling time involved including load from higher-priority sampling times (interrupts).
r9980[0...101]
Sampling times utilization calculated / t_sampl util calc
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Displays the calculated utilizations for the active sampling times based on the existing target topology.
Index:
[0] = Net utilization 0
[1] = Total utilization 0
[2] = Net utilization 1
[3] = Total utilization 1
[4] = Net utilization 2
[5] = Total utilization 2
[6] = Net utilization 3
[7] = Total utilization 3
[8] = Net utilization 4
[9] = Total utilization 4
[10] = Net utilization 5
[11] = Total utilization 5
[12] = Net utilization 6
[13] = Total utilization 6
[14] = Net utilization 7
[15] = Total utilization 7
[16] = Net utilization 8
1-618
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [µs]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [%]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [µs]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [%]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents