Parameter
List of parameters
Index:
[0] = First drive for connection
[1] = Second drive for connection
[2] = Third drive for connection
r4834[0...4]
CO: Function generator free measurement output signal / FG fr MeasFct outp
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN
P-Group: Trace and function generator
Not for motor type: -
Min
- [%]
Description:
Displays the output signal for the free measurement function.
Index:
[0] = Signal 1
[1] = Signal 2
[2] = Signal 3
[3] = Signal 4
[4] = Signal 5
Dependency:
Refer to: p4810
Note:
The signals are only output in the "free measurement function" operating mode (p4810 = 6)
p4835[0...4]
Function generator free measurement function scaling / FG fr MeasFct scal
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN
P-Group: -
Not for motor type: -
Min
-200.00000 [%]
Description:
Sets the scaling of the output signals for the free measurement function.
Index:
[0] = Signal 1
[1] = Signal 2
[2] = Signal 3
[3] = Signal 4
[4] = Signal 5
Note:
The parameter cannot be changed when the measurement function has been started (r4706 = 2, 3).
r5005
Spindle file system status / File sys stat
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the status for the file system on the non-volatile memory.
The individual result data and characteristic data are summarized in a corresponding file.
Bit field:
Bit
Signal name
01
Result data clamping cycle thresholds avail-
able
02
Result data clamping cycle counter avail-
able
03
Result data operating hours counter avail-
able
04
Result data temperature diagnostics avail-
able
05
Result data real time clock synchronization
available
06
Result data speed/torque matrix available
1-476
Calculated: -
Dynamic index: -
Units group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
200.00000 [%]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
- [%]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
100.00000 [%]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
-
No
-
No
-
No
-
No
-
No
-