Parameter
List of parameters
p3299
Variable signaling function, sampling time / Var sig t_sample
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: -
Not for motor type: -
Min
1.000 [ms]
Description:
Sets the sampling time for the variable signaling function.
Notice:
The following must apply for the setting:
Sampling time (p3299) <= pickup delay (p3297), dropout delay (p3298)
Note:
Only the following values can be set:
1.000, 2.000, 3.000, 4.000
p3900
Completion of quick commissioning / Compl quick_comm
SERVO_S110-CAN,
Can be changed: C2(1)
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
0
Description:
Exits quick commissioning (p0010 = 1) with automatic calculation of all parameters of all existing drive data sets
that depend on the entries made during quick commissioning.
p3900 = 1 initially includes a parameter reset (factory setting, the same as p0970 = 1) for all parameters of the drive
object; however, without overwriting the entries made during the quick commissioning.
The interconnections of PROFIBUS PZD telegram selection (p0922) and the interconnections via p0700, p1000
and p1500 are re-established and all of the dependent motor, open-loop and control-loop control parameters are
calculated (corresponding to p0340 = 1).
p3900 = 2 includes the restoration of the interconnections of PROFIBUS PZD telegram selection (p0922) and the
interconnections via p0700, p1000 and p1500 and the calculations corresponding to p0340 = 1.
p3900 = 3 only includes the calculations associated with the motor, open-loop and closed-loop control parameters
corresponding to p0340 = 1.
Value:
0:
1:
2:
3:
Notice:
After the value has been modified, no further parameter modifications can be made and the status is shown in
r3996. Modifications can be made again when r3996 = 0.
Note:
When the calculations have been completed, p3900 and p0010 are automatically reset to a value of 0.
When calculating motor, open-loop and closed-loop control parameters (such as for p0340 = 1) parameters associ-
ated with a selected Siemens catalog motor are not overwritten.
If a catalog motor has not been selected (see p0300), then the following parameters are reset with p3900 > 0 in
order to restore the situation that applied when commissioning the drive for the first time:
for induction motors p0320, p0352, p0353, p0604, p0605, p0626 ... p0628.
for synchronous motors p0326, p0327, p0352, p0353, p0391 ... p0393, p0604, p0605.
r3925[0...n]
Identification final display / Ident final_disp
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Motor
Not for motor type: -
Min
-
Description:
Displays the commissioning steps that have been carried out.
1-434
No quick parameterization
Quick parameterization after parameter reset
Quick parameterization (only) for BICO and motor parameters
Quick parameterization for motor parameters (only)
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
4.000 [ms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
3
Calculated: CALC_MOD_ALL
Dynamic index: DDS, p0180
Units group: -
Scaling: -
Max
-
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: 5301
Unit selection: -
Expert list: 1
Factory setting
4.000 [ms]
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-