Siemens SINAMICS S110 List Manual page 605

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

r9795
SI diagnostics STOP F (Control Unit) / SI diag STOP F CU
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Displays the number of the cross-checked data which has caused STOP F on the Control Unit.
Dependency:
Refer to: r9895
Refer to: F01611
Note:
A complete list of numbers for crosswise-compared data items appears in fault F01611.
r9798
SI actual checksum SI parameters (Control Unit) / SI act_checksum CU
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Displays the checksum over the checked Safety Integrated parameters on the Control Unit (actual checksum).
Dependency:
Refer to: p9799, r9898
p9799
SI reference checksum SI parameters (Control Unit) / SI set_checksum CU
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0000 hex
Description:
Sets the checksum for the checked Safety Integrated parameters on the Control Unit (reference checksum).
Dependency:
Refer to: r9798, p9899
p9801
SI enable, functions integrated in the drive (processor 2) / SI enable fct P2
SERVO_S110-CAN
Can be changed: C2(95)
Data type: Unsigned16
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Sets the enable signals for safety functions on processor 2 that are integrated in the drive.
Not all possible settings may be permissible, depending on the Control Unit and Motor Module or Power Module
being used.
Bit field:
Bit
Signal name
00
STO (SH) via terminals (Motor Module)
enable
02
Motion monitoring functions integr. in the
drive (Motor Module)
Dependency:
Refer to: p9601, r9871
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
STO: Safe Torque Off
SMM: Safe Motion Monitoring
A change only becomes effective after a POWER ON.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
FFFF FFFF hex
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Enable
Enable
Parameter
List of parameters
Access level: 2
Func. diagram: 2802
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 2800
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 2800
Unit selection: -
Expert list: 1
Factory setting
0000 hex
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 bin
0 signal
FP
Inhibit
2810
Inhibit
-
1-605

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents