Siemens SINAMICS S110 List Manual page 552

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
r9451[0...29]
Units changeover adapted parameters / Unit_chngov par
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the parameters whose parameter would have to be changed during a units changeover.
Dependency:
Refer to: F07088
r9481
Number of BICO interconnections / BICO count
All objects
Can be changed: -
Data type: Unsigned16
P-Group: Commands
Not for motor type: -
Min
-
Description:
Displays the number of BICO interconnections (signal sinks).
Dependency:
Refer to: r9482, r9483
Note:
The selected BICO interconnections should be entered into r9482 and r9483.
r9482[0...n]
BICO interconnections BI/CI parameters / BICO BI/CI par
All objects
Can be changed: -
Data type: Unsigned32
P-Group: Commands
Not for motor type: -
Min
-
Description:
Displays the signal sinks (binector/connector inputs, BI/CI parameters).
The number of BICO interconnections is displayed in r9481.
Dependency:
Refer to: r9481, r9483
Note:
The list is sorted according to signal sources and is structured as follows:
r9842[0]: Interconnection 1 (signal sink, BICO coded), r9843[0]: Interconnection 1 (signal source, BICO coded)
r9842[1]: Interconnection 2 (signal sink, BICO coded), r9843[1]: Interconnection 2 (signal source, BICO coded)
...
r9483[0...n]
BICO interconnections BO/CO parameters / BICO BO/CO par
All objects
Can be changed: -
Data type: Unsigned32
P-Group: Commands
Not for motor type: -
Min
-
Description:
Displays the signal sources (binector/connector outputs, BO/CO parameters).
The number of BICO interconnections is displayed in r9481.
Dependency:
Refer to: r9481, r9482
Note:
The list is sorted according to signal sources and is structured as follows:
r9842[0]: Interconnection 1 (signal sink, BICO coded), r9843[0]: Interconnection 1 (signal source, BICO coded)
r9842[1]: Interconnection 2 (signal sink, BICO coded), r9843[1]: Interconnection 2 (signal source, BICO coded)
...
1-552
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: r9481
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: r9481
Units group: -
Scaling: -
Max
-
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents