Siemens SINAMICS S110 List Manual page 860

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

0.000...999 999.000 s
p1120[D] (10.000)
p1122
1 = Bypass ramp-function generator
[2505.3]
r1198.15
p1142
1 = Enable speed setpoint
[2501.3]
r0898.6
Freeze ramp-function generator
0
RFG setpoint at the input
1
r1119
1
[3050.8]
0
0
•1
<4>
p1141
0 = Freeze ramp generator
[2501.3]
r0898.5
1 = Internal RFG enable
[2634.4]
0 = Internal fast stop
[2634.4]
Set ramp-function generator
p1143[C]
(0)
Ramp-function generator setting value
p1144[C]
<1> Effective ramp-up time: Tup_eff = Tup + (IR/2 + FR/2)
Effective ramp-down time: Tdn_eff = Tdn + (IR/2 + FR/2)
<2> p1151.00 = 0: Rounding-off at zero crossover enabled.
p1151.00 = 1: Rounding-off at zero crossover disabled.
<3>
p1134 = 0: Rounding-off is always active.
Overshoots can occur.
p1134 = 1: Final rounding-off is not effective
when the setpoint is suddenly
reduced during ramp-up.
n
<4> Inhibited during jogging.
<5> After a 0/1 signal a ramp-up is started again.
<6> With simultaneous jog 1 and 2 (p1055 = p1056 = 1) the last setpoint remains effective (Freeze ramp-function generator).
<100> Only if the function module "extended setpoint channel" is activated (r0108.8 = 1).
1
2
DO: SERVO
Setpoint channel - Extended ramp-function generator
Ramp-up time
Ramp-down time
0.000...999 999.000 s
p1121[D] (10.000)
0 = Internal fast stop
[2634.4]
0
1
Ramp flattening-off
[3080.8]
y
1
x
Tup
p1082
x
0
0
y
<3>
<6>
-p1082
RFG rounding-off type
dy/dt
IR
0...1
p1134[D] (0)
(0)
Tup_eff <1>
t
t
t
set
3
4
OFF3
OFF3
Ramp-down time
Initial rounding-off
Initial rounding-off
0.000...600.000 s
0.000...30.000 s
0.000...30.000 s
p1135[D] (0.000)
p1136[D] (0.000)
p1130[D] (0.000)
0
1
0
1
0
0
0
1
IR
FR
Tdn
Expanded ramp-function
generator
<2>
FR
IR
FR
IR
FR
IR
Tdn_eff <1>
x
+ –
y
p1082
n_max
[3050.5]
[3095.7]
"Ramp-up/ramp-down active"
0.00...1000.00 rpm
5
fp_3070_98_eng.vsd
30.09.11 V04.04.00
OFF3
Final rounding-off
Final rounding-off
0.000...30.000 s
0.000...30.000 s
p1137[D] (0.000)
p1131[D] (0.000)
0
1
y
1
0
0
1 = Ramp-function
p1140
generator enabled
[2501.3]
r0898.4
<5>
FR
HLG acceleration
t
r1149
Other status bits
1
Ramp-up active
Ramp-down active
0
Ramp-function generator, status bits
Threshold for
p1148[D] (19.80)
6
7
Function diagram
SINAMICS S110
4000.00 μs
Refer to [1020.7]
<100>
n_set_5
[3080.1]
[3080.5]
8
- 3070 -