Parameter
List of parameters
26 ... 100 %:
The encoder is working in the specified range.
Index:
[0] = Incremental
[1] = Reserved
[2] = Abs track
[3] = Code conn
Dependency:
Refer to: p4650
Note:
Value = 999 means:
- the component specified in p4650 is not connected
- the encoder does not support the display of the functional reserve
p4660[0...2]
Sensor Module filter bandwidth / SM Filt_bandw
SERVO_S110-CAN,
Can be changed: C2(4)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
0.00 [kHz]
Description:
Sets the filter bandwidth for Sensor Module SMx10 (resolver) and SMx20 (sin/cos).
The value set on the Sensor Module is displayed in r4661.
The Sensor Module hardware only supports the following values:
- 0: The Sensor Module's default is used.
- 50 kHz
- 170 kHz
- 500 kHz
- Unlimited: Only the bandwidth of the operational amplifier is effective.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: r4661
Note:
A value of zero is displayed if an encoder is not present.
r4661[0...2]
Sensor Module filter bandwidth display / SM Filt_bandw disp
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
- [kHz]
Description:
Display of the effective filter bandwidth for Sensor Module SMx10 (resolver) and SMx20 (sin/cos).
The bandwidth of the filter is set using p4660.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: p4660
Note:
A value of zero is displayed if an encoder is not present.
1-440
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
20000.00 [kHz]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [kHz]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00 [kHz]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [kHz]