Parameter
List of parameters
[15] = Send signal to BO: r8511.15
[16] = Send signal to BO: r8511.16
[17] = Send signal to BO: r8511.17
[18] = Send signal to BO: r8511.18
[19] = Send signal to BO: r8511.19
[20] = Send signal to BO: r8511.20
[21] = Send signal to BO: r8511.21
Dependency:
Refer to: r8511
p8502
CI: Data transfer 0 wordwise / Transfer 0 word
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned32 / Integer32
CU_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the wordwise data transfer (process signal).
This signal value is available in CO: r8512 for further interconnection.
Dependency:
Refer to: r8512
p8503
CI: Data transfer 1 wordwise / Transfer 1 word
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned32 / Integer32
CU_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the wordwise data transfer (process signal).
This signal value is available in CO: r8513 for further interconnection.
Dependency:
Refer to: r8513
p8504
CI: Data transfer 2 wordwise / Transfer 2 word
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned32 / Integer32
CU_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the wordwise data transfer (process signal).
This signal value is available in CO: r8514 for further interconnection.
Dependency:
Refer to: r8514
p8505
CI: Data transfer 3 wordwise / Transfer 3 word
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned32 / Integer32
CU_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the wordwise data transfer (process signal).
This signal value is available in CO: r8515 for further interconnection.
Dependency:
Refer to: r8515
1-494
Calculated: -
Dynamic index: -
Units group: -
Scaling: PERCENT
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: PERCENT
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: PERCENT
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: PERCENT
Max
-
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0