Parameter
List of parameters
p9658
SI transition time STOP F to STOP A (processor 1) / SI STOP F->A P1
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [ms]
Description:
Sets the transition period from STOP F to STOP A on processor 1.
Dependency:
Refer to: r9795, p9858
Refer to: F01611
Note:
For a crosswise data comparison between p9658 and p9858, a difference of one Safety monitoring clock cycle is
tolerated.
The parameterized time is rounded internally to an integer multiple of the monitoring clock cycle.
STOP F: Defect in a monitoring channel (error in the crosswise data comparison)
STOP A: Pulse suppression via the safety shutdown path
p9659
SI forced checking procedure timer / SI FrcdCkProcTimer
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [h]
Description:
Sets the time interval for carrying out the forced checking procedure and testing the Safety shutdown paths.
Within the parameterized time, STO must have been de-selected at least once. The monitoring time is reset each
time that STO is de-selected.
Dependency:
Refer to: A01699
Note:
STO: Safe Torque Off / SH: Safe standstill
r9660
SI forced checking procedure remaining time / SI frc chk remain
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
- [h]
Description:
Displays the time remaining before dynamization and testing of the safety shutdown paths (forced checking proce-
dure).
Dependency:
Refer to: A01699
p9700
SI Motion copy function / SI Mtn copy fct
SERVO_S110-CAN,
Can be changed: C2(95), U, T
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0000 hex
Description:
Setting to start the required copy function.
After starting, the corresponding parameters are copied from processor 1 to processor 2.
Once copying is complete, the parameter is automatically reset to zero.
Value:
0:
29:
1-586
[00 hex] Copy function ended
[1D hex] Start copy function node identifier
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
30000.00 [ms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
9000.00 [h]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [h]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
00D0 hex
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: 2802
Unit selection: -
Expert list: 1
Factory setting
0.00 [ms]
Access level: 3
Func. diagram: 2810
Unit selection: -
Expert list: 1
Factory setting
8.00 [h]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [h]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 hex