Siemens SINAMICS S110 List Manual page 495

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

r8510.0...7
BO: Data transfer 0 receive bitwise / Trans 0 recv bit
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the signals of the bitwise received data.
These signals were interconnected and transferred via BI: p8500[0...7].
Bit field:
Bit
Signal name
00
Receive signal from BI: p8500
01
Receive signal from BI: p8500
02
Receive signal from BI: p8500
03
Receive signal from BI: p8500
04
Receive signal from BI: p8500
05
Receive signal from BI: p8500
06
Receive signal from BI: p8500
07
Receive signal from BI: p8500
Dependency:
Refer to: p8500
r8511.0...21
BO: Data transfer 1 receive bitwise / Trans 1 recv bit
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the signals of the bitwise received data.
These signals were interconnected and transferred via BI: p8501[0...15].
Bit field:
Bit
Signal name
00
Receive signal from BI: p8501
01
Receive signal from BI: p8501
02
Receive signal from BI: p8501
03
Receive signal from BI: p8501
04
Receive signal from BI: p8501
05
Receive signal from BI: p8501
06
Receive signal from BI: p8501
07
Receive signal from BI: p8501
08
Receive signal from BI: p8501
09
Receive signal from BI: p8501
10
Receive signal from BI: p8501
11
Receive signal from BI: p8501
12
Receive signal from BI: p8501
13
Receive signal from BI: p8501
14
Receive signal from BI: p8501
15
Receive signal from BI: p8501
16
Receive signal from BI: p8501
17
Receive signal from BI: p8501
18
Receive signal from BI: p8501
19
Receive signal from BI: p8501
20
Receive signal from BI: p8501
21
Receive signal from BI: p8501
Dependency:
Refer to: p8501
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
ON
ON
ON
ON
ON
ON
ON
ON
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Parameter
List of parameters
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
OFF
-
OFF
-
OFF
-
OFF
-
OFF
-
OFF
-
OFF
-
OFF
-
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
OFF
-
OFF
-
OFF
-
OFF
-
OFF
-
OFF
-
OFF
-
OFF
-
OFF
-
OFF
-
OFF
-
OFF
-
OFF
-
OFF
-
OFF
-
OFF
-
OFF
-
OFF
-
OFF
-
OFF
-
OFF
-
OFF
-
1-495

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents