Parameter
List of parameters
r3114.9...11
CO/BO: Messages status word global / Msg ZSW global
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the global status word for messages.
The appropriate bit is set if at least one message is present at the drive objects.
Bit field:
Bit
Signal name
09
Alarm present
10
Fault present
11
Safety message present
Note:
The status bits are displayed with delay.
r3115[0...63]
Fault drive object initiating / F DO initiating
All objects
Can be changed: -
Data type: Integer32
P-Group: Messages
Not for motor type: -
Min
-
Description:
Displays the drive object number of the initiating drive object for this fault as integer number.
Value = 63:
The fault was initiated by the drive object itself.
Dependency:
Refer to: r0945, r0947, r0948, r0949, r2109, r2130, r2133, r2136, r3120, r3122
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
The structure of the fault buffer and the assignment of the indices is shown in r0945.
p3116
BI: Acknowledgement automatically suppressed / Ackn suppress
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned32 / Binary
CU_S110-PN
P-Group: Messages
Not for motor type: -
Min
-
Description:
Sets the signal source for the automatic acknowledgement on the device drive object.
BI: p3116 = 0 signal
Faults present are automatically acknowledged on the device drive object. Local device faults are forwarded to the
first active drive object.
BI: p3116 = 1 signal
Faults present are not automatically acknowledged on the device drive object. Local device faults are not for-
warded.
Dependency:
Refer to: p2102, p2103, p2104, p2105, p3981
Note:
When selecting a standard telegram, the BICO interconnection for control signal STW1.10 (master control by PLC)
is automatically established.
1-428
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
8065
No
8060
No
-
Access level: 3
Func. diagram: 1750, 8060
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 8060
Unit selection: -
Expert list: 1
Factory setting
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents