Siemens SINAMICS S110 List Manual page 448

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
17:
18:
19:
20:
21:
22:
30:
35:
36:
37:
38:
Dependency:
Refer to: p4690, p4692, p4693
Notice:
Once SMI/DQI data has been deleted or downloaded successfully, the component has to be powered up.
Note:
SMI: SINAMICS Sensor Module Integrated
DLQ encoder: DRIVE-CLiQ encoder
Help for error value = 11:
- Save the data for the original SMI on the memory card.
- Use an SMI with a suitable hardware version.
Help for error value = 12:
- Set the correct component number or connect the component.
Help for error value = 15:
- Check the DRIVE-CLiQ wiring for the component.
Help for error value = 16:
- Check the DRIVE-CLiQ wiring for the component.
Help for error value = 17:
- Save the data for the original SMI on the memory card.
Help for error value = 18:
- Set parameter p4693 to an appropriate value.
Help for error value = 19:
- Perform an SMI delete or use a blank SMI.
Help for error value = 20:
- Use an SMI card that is not blank.
Help for error value = 21:
- Set the correct component number (p4690).
Note for error value = 22:
- Data cannot be downloaded for component.
Help for error value = 35:
- Reset parameter p4691 to 30.
Help for error value = 37:
- Set the access level to Expert or higher.
Help for error value = 38:
- Set the correct component number (p4690 >= 200).
p4692
SMI spare part save data of all SMIs / Save SMI data
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Integer16
CU_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
0
Description:
Setting to back up the data of all SMIs and DQIs featured in the target topology.
Value:
0:
1:
10:
13:
1-448
Data backup does not match parameterized encoder/motor
Data backup directory not permissible
Component already contains data
Component does not contain any data
Component is not an SMI or a DQI
SMI data cannot be downloaded for component
Delete SMI data
Confirmation of SMI data delete required
SMI data deleted and POWER ON required for component
Access level not sufficient for delete
Delete SMI data not permitted for component
Inactive
Save data of all SMIs and DQIs
Save all data successful
Insufficient memory space for backup
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
29
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0

Hide quick links:

Advertisement

Table of Contents
loading