Parameter
List of parameters
r4709[0...1]
Trace memory space required for measuring functions / Trace mem required
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: Trace and function generator
Not for motor type: -
Min
-
Description:
Displays the memory space required for the current parameter setting in bytes, if the trace is used for the measur-
ing functions.
Index:
[0] = Trace 0
[1] = Trace 1
Dependency:
Refer to: r4799
p4710[0...1]
Trace trigger condition / Trace Trig_cond
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Integer16
CU_S110-PN
P-Group: Trace and function generator
Not for motor type: -
Min
1
Description:
Sets the trigger condition for the trace.
Value:
1:
2:
3:
4:
5:
6:
7:
Index:
[0] = Trace 0
[1] = Trace 1
p4711[0...5]
Trace trigger signal / Trace trig_signal
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: Trace and function generator
Not for motor type: -
Min
-
Description:
Selects the trigger signal for the trace.
Index:
[0] = Trace 0 parameter in BICO format
[1] = Trace 1 parameter in BICO format
[2] = Trace 0 PINx with DO Id and chart Id
[3] = Trace 0 PINx with block Id and PIN Id
[4] = Trace 1 PINy with DO Id and chart Id
[5] = Trace 1 PINy with block Id and PIN Id
Dependency:
Only effective when p4710 does not equal 1.
Note:
It only makes sense to trace the PINs using the commissioning software.
For index 2(4) and 3(5) equal to zero, index 0(1) can only be written and vice versa.
Re index 0 ... 1:
Here, the trigger signal for trace 0 or 1 is entered as parameter in the BICO format.
For trace with a physical address (p4789), the data type of the trigger signal is set here.
1-452
Immediate start
Positive edge
Negative edge
Entry to hysteresis band
Leaving hysteresis band
Trigger at bit mask
Start with function generator
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
7
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
2
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0