Siemens SINAMICS S110 List Manual page 570

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
Index:
[0] = Track assignment SCA1
[1] = Track assignment SCA2
[2] = Track assignment SCA3
[3] = Track assignment SCA4
[4] = Track assignment SCA5
[5] = Track assignment SCA6
[6] = Track assignment SCA7
[7] = Track assignment SCA8
[8] = Track assignment SCA9
[9] = Track assignment SCA10
[10] = Track assignment SCA11
[11] = Track assignment SCA12
[12] = Track assignment SCA13
[13] = Track assignment SCA14
[14] = Track assignment SCA15
[15] = Track assignment SCA16
[16] = Track assignment SCA17
[17] = Track assignment SCA18
[18] = Track assignment SCA19
[19] = Track assignment SCA20
[20] = Track assignment SCA21
[21] = Track assignment SCA22
[22] = Track assignment SCA23
[23] = Track assignment SCA24
[24] = Track assignment SCA25
[25] = Track assignment SCA26
[26] = Track assignment SCA27
[27] = Track assignment SCA28
[28] = Track assignment SCA29
[29] = Track assignment SCA30
Dependency:
Refer to: p9501, p9503
Refer to: F01681
Note:
A change only becomes effective after a POWER ON.
SCA: Safe Cam
p9540
SI Motion SCA tolerance (processor 1) / SI Mtn SCA tol P1
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0.0010 [mm]
Description:
Sets the tolerance for the function "Safe Cam" (SCA).
Within this tolerance, both monitoring channels may signal different signal states of the same safe cam.
Note:
A change only becomes effective after a POWER ON.
p9540
SI Motion SCA tolerance (processor 1) / SI Mtn SCA tol P1
SERVO_S110-CAN
Can be changed: U, T
(Safety rot),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Safety Integrated
(Safety rot),
Not for motor type: -
SERVO_S110-PN
(Safety rot)
Min
0.0010 [°]
Description:
Sets the tolerance for the function "Safe Cam" (SCA).
Within this tolerance, both monitoring channels may signal different signal states of the same safe cam.
Note:
A change only becomes effective after a POWER ON.
1-570
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
10.0000 [mm]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
10.0000 [°]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.1000 [mm]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.1000 [°]