Siemens SINAMICS S110 List Manual page 685

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

p20132
AVA 0 run sequence / AVA 0 RunSeq
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
0
Description:
Setting parameter for the run sequence of instance AVA 0 within the run-time group set in p20131.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20133
CI: AVA 1 input X / AVA 1 input X
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Unsigned32 / FloatingPoint32
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-
Description:
Sets the signal source of the input quantity X of instance AVA 1 of the absolute value generator with sign evalua-
tion.
r20134
CO: AVA 1 output Y / AVA 1 output Y
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-
Description:
Display parameter for output quantity Y of instance AVA 1 of the absolute value generator with sign evaluation.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
32000
Calculated: -
Dynamic index: -
Units group: -
Scaling: PERCENT
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: PERCENT
Max
-
Parameter
List of parameters
Access level: 1
Func. diagram: 7224
Unit selection: -
Expert list: 1
Factory setting
340
Access level: 1
Func. diagram: 7224
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 7224
Unit selection: -
Expert list: 1
Factory setting
-
1-685